six GUID partitions were created. The testing was meant to acquire partition 4 as a<br />

NTFS partition. Table 4.16 shows the test results <strong>of</strong> test case TC-16(1).<br />

Table 4.16<br />

TC-16(1) Result Summary<br />

Tested<br />

Assertions<br />

Failed<br />

Assertions<br />

FTK Imager Helix 3 Pro AIR<br />

AFR01-05, AFR07, AIC01-02, AIC05-08, ALOG01-03<br />

None<br />

AFR-01 & 03 Passed<br />

AFR-02 FAILED<br />

Others are N/A<br />

85<br />

None<br />

Pass Rate (%) 100% 33.33% 100%<br />

FTK Imager was able to read the partition in<strong>for</strong>mation from the test drive and to<br />

display it correctly to the user. All data acquired <strong>for</strong> the NTFS partition were correct<br />

and complete. Helix 3 Pro was not able to identify the six pre-configured GUID<br />

partitions in the test drive. Only the whole drive acquisition option was available. AIR<br />

achieved the expected result in this test case. AIR acquired the single GUID partition<br />

successfully and the images produced were complete and accurate.<br />

4.2.2.15 TC-16(2): Acquiring A GPT <strong>Disk</strong><br />

The pervious test case TC-16(1) tested if the imaging tools were able to acquire a<br />

single GUID partition. The test case TC-16(2) tested if the tested tools could acquire a<br />

whole GPT disk. FTK Imager displayed to the user the correct partition in<strong>for</strong>mation <strong>of</strong><br />

the test drive and all data acquired were correct and complete.<br />

Table 4.17<br />

TC-16(2) Result Summary<br />

Tested<br />

Assertions<br />

Failed<br />

Assertions<br />

Pass Rate<br />

(%)<br />

FTK Imager Helix 3 Pro AIR<br />

AFR01-05, AFR07, AIC01-02, AIC05-08, ALOG01-03<br />

None ALOG02 None<br />

100% 93.33% 100%