FTK Imager 2.9.0.1385 (Release Date: 8 th , Apr 2010)<br />

1.17 TC-07- Insufficient space & TC-08<br />

Test Case TC-07-Insufficient space & TC-08 (FTK Imager 2.9.0.1385)<br />

Test &<br />

Case<br />

Summary:<br />

Attempt to create an image file where destination device has insufficient<br />

space , and see whether the tool notifies the user and <strong>of</strong>fer another<br />

destination device to continue<br />

Assertion: AFR-01 The tool accesses the digital source with a supported access interface<br />

AFR-02 The tool acquires a digital source<br />

AFR-03 The tool operates in an execution environment<br />

AFR-04 The tool creates an image file <strong>of</strong> the digital source<br />

AFR-05 The tool acquires all the visible data sectors from the digital source<br />

AFR-07 All data sectors acquired from the digital source are acquired accurately.<br />

AIC-04 The tool reports to the user if insufficient space in the destination device<br />

during the image creation process.<br />

AIC-05 If multi-file image creation and the image file size is selected, the tool<br />

creates a multi-file image except that one file may be smaller<br />

AIC-10 The tool reports to the user if insufficient space in the destination device to<br />

contain the multi-image file creation and if destination device switching<br />

function is supported, the image is continue on the selected destination<br />

device.<br />

ALOG-01 If the tool logs any in<strong>for</strong>mation regarding to the acquisition, the<br />

in<strong>for</strong>mation is accurately logged in the log file.<br />

ALOG-02 The tool display correct in<strong>for</strong>mation about the acquisition to the user.<br />

ALOG-03 The tool display correct in<strong>for</strong>mation regarding to the acquisition to the<br />

user and the in<strong>for</strong>mation displayed is consistent with the log file if the log<br />

file function is supported<br />

Source<br />

Device:<br />

Drive<br />

Setup:<br />

Partition<br />

Table:<br />

Log<br />

highlights:<br />

Drive Model: ST380811 AS (80GB)<br />

Serial Number: 6PS2CA4Z<br />

Sector count: 156,296,385<br />

Write blocker: Tableau <strong>Forensic</strong> SATA/IDE Bridge IEEE 1394 SBP2<br />

Device<br />

/dev/sdc: current max LBA: 156,296,385<br />

/dev/sdc: native max LBA: 156,296,385<br />

/dev/sdc: physical max LBA: 156,296,385<br />

/dev/sdc: HPA not set<br />

/dev/sdc: DCO not set<br />

Device Start End #sectors System<br />

unallocated 0 156296384 156296385 Empty<br />

183