<strong>Multichannel</strong> <strong>PRA</strong><br />

• Constant Extension length: The last n digits are interpreted as the extension, the<br />

rest (to the left) as CLI, where n is given in Length of the constant part<br />

After splitting the calling number into CLI and extension, the CLI will be prefixed by<br />

the Prefix for CLI reconstruction (if any is given) and sent together with the<br />

extension in a SETUP message to the PBX.<br />

Note: The SETUP is sent immediately, independently from the settings in the Dial<br />

mode parameter.<br />

Example: A call comes in from the number 05498765 to the extension 1234.<br />

According to the settings in the above screen copy the four displayed channels 1 to 4<br />

(left to right) will expect the following CLI:<br />

Channel 1: 05498765#1234<br />

Channel 2: 054987651234<br />

Channel 3: 4987651234<br />

Channel 4: 4987651234<br />

In all four cases the resulting SETUP to the PBX will have the Calling number (CLI)<br />

05498765 and the Called number 1234.<br />

The CLIR Encoding can be used by the network to signal a call with the CLI rejected<br />

to the <strong>Multichannel</strong> <strong>PRA</strong>. If a string is entered in this field and the CLI is equal to that<br />

string the call will be signaled to the PBX as PRIVATE by omitting the CLI in the<br />

SETUP message.<br />

Example: A call comes in on channel 1 from 0#1234. The resulting CLI would be 0.<br />

Since this is given as CLIR Encoding string, the CLI is not sent to the PBX.<br />

6.5.3 TDMA parameters<br />

These parameters are for use with TDMA modules.<br />

Normally you only have to give the MIN (directory number) of the module and the SID<br />

(System ID) of the home network.<br />

If a TDMA module logs in to an analog AMPS network you can try enter 2 or 3 in the<br />

EDSS parameter to prevent this.<br />

6.5.4 Service parameters<br />

These parameters are not intended to be changed by the user. They are for service<br />

purposes only.<br />