Chapter 2: <strong>Installation</strong><br />

2. Place a jumper on pins 1 <strong>and</strong> 2 to set the module for Remote<br />

control, or pins 2 <strong>and</strong> 3 to set the module for Local control. See<br />

Figure 2-2.<br />

Figure 2-2. Remote/Local Control Settings<br />

Note<br />

1 2 3 1 2 3<br />

Remote control Local control<br />

You must configure modules for local or remote operation prior to<br />

power-up. To change the configuration, first remove power from the<br />

module, reset the jumper, <strong>and</strong> then reapply power. The white<br />

triangle near the jumper pins on the module indicates pin 1.<br />

See Table 1-1 on page 7 for more information on local/remote control<br />

jumper functionality.<br />

External Reference Termination Jumper<br />

Follow this procedure to set the external Reference Input Termination<br />

jumper:<br />

1. Locate jumper J1 on the module.<br />

(Figure 2-1 on page 14 shows the location of the jumper.)<br />

2. Place a jumper on pins 1 <strong>and</strong> 2 to set the module for 75Ω<br />

Termination, or pins 2 <strong>and</strong> 3 for No Termination (see Figure 2-3).<br />

1 2 3 1 2 3<br />

75Ω Termination<br />

No Termination<br />

Figure 2-3. Genlock Termination Settings<br />

XHD6801+ <strong>Installation</strong> <strong>and</strong> <strong>Operation</strong> <strong>Manual</strong> 15