NOx Emissions Impacts from Widespread Deployment of CHP in ...
NOx Emissions Impacts from Widespread Deployment of CHP in ...
NOx Emissions Impacts from Widespread Deployment of CHP in ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CHP</strong> Results<br />
<strong>CHP</strong> Technology: Microturb<strong>in</strong>e<br />
Fuel: Natural Gas<br />
Unit Capacity: 250 kW<br />
Number <strong>of</strong> Units: 1<br />
Total <strong>CHP</strong> Capacity: 250 kW<br />
Operation: 5,840 hours per year<br />
Heat Rate: 13,084 Btu/kWh HHV<br />
<strong>CHP</strong> Fuel Consumption: 19,102 MMBtu/year<br />
Duct Burner Fuel Consumption: - MMBtu/year<br />
Total Fuel Consumption: 19,102 MMBtu/year<br />
Total <strong>CHP</strong> Generation: 1,460 MWh/year<br />
Useful <strong>CHP</strong> Thermal Output: 3,563 MMBtu/year for thermal applications (non-cool<strong>in</strong>g)<br />
1,851 MMBtu/year for electric applications (cool<strong>in</strong>g and electric heat<strong>in</strong>g)<br />
5,415 MMBtu/year Total<br />
Displaced On-Site Production for Exist<strong>in</strong>g Gas Boiler<br />
Thermal (non-cool<strong>in</strong>g) Applications: 0.10 lb/MMBtu <strong>NOx</strong><br />
0.00% sulfur content<br />
Displaced Electric Service (cool<strong>in</strong>g and electric<br />
heat<strong>in</strong>g): 54 tons <strong>of</strong> cool<strong>in</strong>g capacity <strong>from</strong> <strong>CHP</strong> system<br />
<strong>CHP</strong>: S<strong>in</strong>gle-Effect Absorption Chiller<br />
Replaces: 1.60 kW/ton (COP=2.2) 1980-v<strong>in</strong>tage, Ro<strong>of</strong>-top unit