<strong>CHP</strong> Results<br />

<strong>CHP</strong> Technology: Microturb<strong>in</strong>e<br />

Fuel: Natural Gas<br />

Unit Capacity: 250 kW<br />

Number <strong>of</strong> Units: 1<br />

Total <strong>CHP</strong> Capacity: 250 kW<br />

Operation: 5,840 hours per year<br />

Heat Rate: 13,084 Btu/kWh HHV<br />

<strong>CHP</strong> Fuel Consumption: 19,102 MMBtu/year<br />

Duct Burner Fuel Consumption: - MMBtu/year<br />

Total Fuel Consumption: 19,102 MMBtu/year<br />

Total <strong>CHP</strong> Generation: 1,460 MWh/year<br />

Useful <strong>CHP</strong> Thermal Output: 3,563 MMBtu/year for thermal applications (non-cool<strong>in</strong>g)<br />

1,851 MMBtu/year for electric applications (cool<strong>in</strong>g and electric heat<strong>in</strong>g)<br />

5,415 MMBtu/year Total<br />

Displaced On-Site Production for Exist<strong>in</strong>g Gas Boiler<br />

Thermal (non-cool<strong>in</strong>g) Applications: 0.10 lb/MMBtu <strong>NOx</strong><br />

0.00% sulfur content<br />

Displaced Electric Service (cool<strong>in</strong>g and electric<br />

heat<strong>in</strong>g): 54 tons <strong>of</strong> cool<strong>in</strong>g capacity <strong>from</strong> <strong>CHP</strong> system<br />

<strong>CHP</strong>: S<strong>in</strong>gle-Effect Absorption Chiller<br />

Replaces: 1.60 kW/ton (COP=2.2) 1980-v<strong>in</strong>tage, Ro<strong>of</strong>-top unit