Deactivating System<br />
CAUTION: Always turn off (Deactivate and Disable)<br />
AutoTrac system before entering a roadway.<br />
To turn off AutoTrac from GUIDANCE VIEW<br />
tab, toggle STEER ON/OFF button until<br />
STEER OFF is displayed.<br />
AutoTrac system can be made DEACTIVE by following<br />
methods:<br />
• Turning steering wheel.<br />
StarFire<br />
AutoTrac controller takes its StarFire Height and Fore-Aft<br />
measurements from the StarFire setup. To change<br />
this information select the menu button then select the<br />
StarFire button. The StarFire main page will appear.<br />
Select the Setup tab (A) at the top of the screen.<br />
StarFire Height (in.) Enter the height of the StarFire<br />
receiver into the Height box (C) of the StarFire Setup<br />
screen. Height is measured from the ground to the center<br />
(where the green and yellow meet) of the dome.<br />
StarFire Fore-Aft (in.) Enter the Fore-Aft measurement<br />
into the Fore/Aft box (B) of the StarFire Setup screen.<br />
This is the distance from the fixed axle of the machine to<br />
the receiver. The fixed axle is the rear axle on a row crop<br />
tractor. The fixed axle is the front axle on an articulated<br />
tractor<br />
NOTE: For more information on StarFire setup<br />
see the StarFire operators manual that<br />
matches your equipment.<br />
A—Setup tab<br />
B—Fore/Aft<br />
C—Height<br />
GS3 Display 2630<br />
25-2<br />
• Slowing to speeds less than 0.5 km/h (0.3 mph).<br />
• Exceeding forward speed of<br />
Tractor - 30 km/h (18.6 mph)<br />
Sprayer - 37 km/h (23 mph)<br />
Combine - 20 km/h (12.4 mph)<br />
• Exceeding reverse speed of 10 km/h (6.0 mph).<br />
• Toggle STEER ON/OFF button until STEER OFF is<br />
displayed in GUIDANCE VIEW tab.<br />
• Operator out of seat for more than 5 seconds if using<br />
seat switch or no activity detected by operator presence<br />
monitor for 7 minutes.<br />
PC8663 —UN—05AUG05<br />
PC13738 —UN—17MAY11<br />
Menu Button<br />
SF3000 Button<br />
StarFire Setup Screen<br />
OUO6050,0000D68 -19-22SEP07-1/1<br />
PC13726 —UN—19MAY11<br />
BA31779,00003BD -19-21FEB12-1/1<br />
031312<br />
PN=28