26.09.2013 Views

HS-105P, PE. SA AutoCam™ Pan & Tilt Head - Vinten Radamec

HS-105P, PE. SA AutoCam™ Pan & Tilt Head - Vinten Radamec

HS-105P, PE. SA AutoCam™ Pan & Tilt Head - Vinten Radamec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>HS</strong>-<strong>105P</strong> Installation<br />

Electrical Clip Limits<br />

Three sets of jumpers (J1, J2 and sections of J3) determine the electrical range<br />

of the pan and tilt servos. Positions 2 and 3 of J3 set the overall range of both<br />

pan and tilt to ±180°, ±90°, ±45° or ±22.5°.<br />

J1 sets the pan clip limit within the overall range and J2 sets the tilt clip within<br />

the overall range. The location of these jumpers is shown below with the possible<br />

settings for J3 (positions 2 and 3 only) highlighted - shaded = jumper<br />

installed. The other jumpers are described later.<br />

<strong>Pan</strong> Clip<br />

<strong>Tilt</strong> Clip<br />

J9<br />

RS422<br />

9600<br />

1<br />

1<br />

J1<br />

J2<br />

2400<br />

J6<br />

1<br />

J3<br />

Miscellaneous Functions<br />

<strong>HS</strong>-<strong>105P</strong> Jumper Locations<br />

3-18 User Manual<br />

1<br />

1<br />

1<br />

1<br />

J3<br />

J3<br />

J3<br />

J3<br />

Range = ±180°<br />

Range = ±90°<br />

Range = ±45°<br />

Range = ±22.5°