HS-105P, PE. SA AutoCam™ Pan & Tilt Head - Vinten Radamec
HS-105P, PE. SA AutoCam™ Pan & Tilt Head - Vinten Radamec
HS-105P, PE. SA AutoCam™ Pan & Tilt Head - Vinten Radamec
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>HS</strong>-<strong>105P</strong> Installation<br />
Electrical Clip Limits<br />
Three sets of jumpers (J1, J2 and sections of J3) determine the electrical range<br />
of the pan and tilt servos. Positions 2 and 3 of J3 set the overall range of both<br />
pan and tilt to ±180°, ±90°, ±45° or ±22.5°.<br />
J1 sets the pan clip limit within the overall range and J2 sets the tilt clip within<br />
the overall range. The location of these jumpers is shown below with the possible<br />
settings for J3 (positions 2 and 3 only) highlighted - shaded = jumper<br />
installed. The other jumpers are described later.<br />
<strong>Pan</strong> Clip<br />
<strong>Tilt</strong> Clip<br />
J9<br />
RS422<br />
9600<br />
1<br />
1<br />
J1<br />
J2<br />
2400<br />
J6<br />
1<br />
J3<br />
Miscellaneous Functions<br />
<strong>HS</strong>-<strong>105P</strong> Jumper Locations<br />
3-18 User Manual<br />
1<br />
1<br />
1<br />
1<br />
J3<br />
J3<br />
J3<br />
J3<br />
Range = ±180°<br />
Range = ±90°<br />
Range = ±45°<br />
Range = ±22.5°