25.10.2013 Views

Request

Request

Request

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

• The scenario is: as a <strong>Request</strong>er,<br />

− It sends a request TLP out to a completer, which could be RC or EP<br />

− The completer for some reason treats this request as an Unsupported <strong>Request</strong>:<br />

If the original request TLP is Posted, the completer discards this UR request, however will<br />

return NO completion. It may send PCIe error message toward the RC.<br />

If the original request TLP is Non-Posted (MRd for example), the completer will return a<br />

Completion with UR status.<br />

<strong>Request</strong>er<br />

Root<br />

Complex<br />

or<br />

Switch<br />

I am here!<br />

Why do you send me<br />

an UR Completion?<br />

TM<br />

UR<br />

Completion<br />

TLP<br />

41<br />

MRd <strong>Request</strong><br />

TLP<br />

ERR_x<br />

Message<br />

PCIe Error Message<br />

Completer<br />

End<br />

point<br />

Freescale, the Freescale logo, AltiVec, C-5, CodeTEST, CodeWarrior, ColdFire, ColdFire+, C-Ware, the Energy Efficient Solutions logo, Kinetis,<br />

mobileGT, PowerQUICC, Processor Expert, QorIQ, Qorivva, StarCore, Symphony and VortiQa are trademarks of Freescale Semiconductor, Inc.,<br />

Reg. U.S. Pat. & Tm. Off. Airfast, BeeKit, BeeStack, CoreNet, Flexis, MagniV, MXC, Platform in a Package, QorIQ Qonverge, QUICC Engine,<br />

Ready Play, SafeAssure, the SafeAssure logo, SMARTMOS, TurboLink, Vybrid and Xtrinsic are trademarks of Freescale Semiconductor, Inc. All<br />

other product or service names are the property of their respective owners. © 2012 Freescale Semiconductor, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!