1. Use the boot system command to set Image2 as the code to install on the next reboot of Unit 2, and<br />

then inspect the show bootvar output again to verify the selection of Image2 in “next-active”:<br />

<strong>Force10</strong>-S50 #boot system 2 image2<br />

Activating image image2 ..<br />

<strong>Force10</strong>-S50 #show bootvar<br />

Image Descriptions<br />

image1 : default image<br />

image2 :<br />

Images currently available on Flash<br />

-------------------------------------------------------------------unit<br />

image1 image2 current-active next-active<br />

--------------------------------------------------------------------<br />

1 F.10.20.1 image1 image1<br />

2 F.10.16.2 F.10.20.1 image1 image2<br />

Figure 69 Using the show bootvar Command within a Stack<br />

2. After executing the reload 2 command to reboot Unit 2, use the show switch command to verify<br />

that the stack is running the new code:<br />

<strong>Force10</strong>-S50 #reload 2<br />

Are you sure you want to reload the switch? (y/n) y<br />

Reloading switch 2.<br />

................<br />

<strong>Force10</strong>-S50 #STACK: master on 0:1:e8:d5:c2:21 (2 cpus, 12 units)<br />

Trying to attach more units.....<br />

STACK: master on 0:1:e8:d5:c2:21 (2 cpus, 12 units)<br />

STACK: attach 7 units on 1 cpu<br />

This switch is manager of the stack.<br />

<strong>Force10</strong>-S50 >show switch<br />

Management Preconfig Plugged-in Switch Code<br />

Switch Status Model ID Model ID Status Version<br />

------ ------------ ---------------- ---------------- --------------- --------<br />

1 Mgmt Switch SA-01-GE-48T SA-01-GE-48T OK F.10.20.1<br />

2 Stack Member SA-01-GE-48T SA-01-GE-48T OK F.10.20.1<br />

<strong>Force10</strong>-S50 #show stack<br />

Configured Running<br />

Stack Stack Link Link<br />

Unit Interface Mode Mode Status Speed (Gb/s)<br />

---- ---------------- ---------- ---------- ------------ ------------<br />

1 Stack Port A N/A Stack Link Up 10<br />

1 Stack Port B N/A Stack Link Up 10<br />

2 Stack Port A N/A Stack Link Up 10<br />

2 Stack Port B N/A Stack Link Up 10<br />

Figure 70 Verifying Stack Sequencing after a Reload with show switch and show stack Commands<br />

SFTOS Configuration Guide, Version <strong>2.5.2</strong>.0 115