Getting Help From the CLI<br />

The following help commands are the same as those found in the E-Series:<br />

• Use “?” at the prompt to get a list of commands in that mode: “<strong>Force10</strong># ?”<br />

• Use “?” with a partial command to see what initial command words in that mode begin with that string:<br />

“<strong>Force10</strong># i?”<br />

• Use “?” after a command or partial command to get a list of commands that start with that word:<br />

“<strong>Force10</strong># ip ?”<br />

Controlling Pagination<br />

Starting in SFTOS Release 2.3, you can use the terminal length command to set how much of the output<br />

of a CLI “show” command to display. Use the show terminal command to display the current setting of<br />

the terminal length command. For details, see the System Configuration Commands chapter in the<br />

SFTOS Command Line Reference.<br />

Checking Status<br />

SFTOS follows the industry convention of using “show” commands to generate status reports through the<br />

command interface.<br />

Viewing the Software Version and Switch Numbers<br />

If you are concerned that you might not have the correct software version, you can select from several<br />

commands to see the installed code version. The following is an example of using show switch , which<br />

you can execute in either User Exec or Privileged Exec modes:<br />

<strong>Force10</strong> #show switch<br />

Management Preconfig Plugged-in Switch Code<br />

Switch Status Model ID Model ID Status Version<br />

------ ------------ ------------- ------------- --------------------- --------<br />

1 Mgmt Switch SA-01-GE-48T SA-01-GE-48T OK 2.3.1<br />

<strong>Force10</strong> #<br />

Figure 5 Using the show switch Command<br />

The Switch column shows the switch ID, which is useful if the switch is in a stack. For example, if the<br />

switch ID were 2, the switch’s physical interfaces would be identified as 2/0/port-number.<br />