Blind actuator 1-gang flush-mounted Order-No. 2165 00 - Gira
Blind actuator 1-gang flush-mounted Order-No. 2165 00 - Gira
Blind actuator 1-gang flush-mounted Order-No. 2165 00 - Gira
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Software "Venetian blind, input 20BD11"<br />
Object table<br />
Function:<br />
Short time operation<br />
Object<br />
h 37<br />
Function<br />
Short time operation<br />
Name<br />
Output 1<br />
Type<br />
1-bit<br />
DPT<br />
1.<strong>00</strong>7<br />
Flag<br />
C, S, - 1<br />
Description<br />
1-bit object for activation of short time operation or for stopping a drive<br />
movement.<br />
Function:<br />
Forced position<br />
Object<br />
h 38<br />
Function<br />
Forced position<br />
Name<br />
Output 1<br />
Type<br />
2-bit<br />
DPT<br />
2.<strong>00</strong>8<br />
Flag<br />
C, S, - 1<br />
Description<br />
2-bit object for forced control. The object state after bus voltage return can be<br />
predefined by means of a parameter.<br />
Function:<br />
Light scene function<br />
Object<br />
h 39<br />
Function<br />
Scene extension<br />
Name<br />
Output 1<br />
Type<br />
1 byte<br />
DPT<br />
18.<strong>00</strong>1<br />
Flag<br />
C, S, - 1<br />
Description<br />
1-byte object for recalling scenes or for storing new scene values.<br />
Function:<br />
Sun protection function<br />
Object<br />
h 41<br />
Function<br />
Automatic mode<br />
Name<br />
Output 1<br />
Type<br />
1-bit<br />
DPT<br />
1.<strong>00</strong>3<br />
Flag<br />
C, S, - 1<br />
Description<br />
1-bit object for activation or deactivation of the automatic sun protection in the<br />
extended sun protection mode<br />
("1" = automatic mode activated / "0" = automatic mode deactivated). The<br />
object is only visible, if the automatic sun protection is to be tracked<br />
immediately when the state of the automatic object changes (parameter<br />
setting).<br />
Function:<br />
Sun protection function<br />
Object<br />
h 42<br />
Function<br />
Automatic mode disable<br />
Name<br />
Output 1<br />
Type<br />
1-bit<br />
DPT<br />
1.<strong>00</strong>3<br />
Flag<br />
C, S, - 1<br />
Description<br />
1-bit object for disabling of the automatic sun protection in the extended sun<br />
protection mode. The polarity can be configured. The object is only visible, if<br />
the automatic sun protection is to be tracked immediately when the state of<br />
the automatic object changes (parameter setting).<br />
1: For reading, the R-flag must be set. The last value written to the object via the bus will be<br />
read.<br />
<strong>Order</strong>-<strong>No</strong>. <strong>2165</strong> <strong>00</strong><br />
Page 22 of 149