04.01.2014 Views

Günther Heisskanaltechnik & Heisskanalsysteme, Hot runner

Günther Heisskanaltechnik & Heisskanalsysteme, Hot runner

Günther Heisskanaltechnik & Heisskanalsysteme, Hot runner

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

User Manual <strong>Hot</strong> Runner Systems DPK<br />

3.4 Operating Mode<br />

GÜNTHER<br />

<strong>Hot</strong> Runner Systems<br />

3.4.1 Changing Set Values<br />

During the single-channel mode move the mark to the set value, by pressing the „"“ key. The<br />

desired set value is entered by pressing the key „#“ and „$“. The key function is dynamic i.e.<br />

the longer the key is pressed, the quicker the set point value changes.<br />

GÜNTHER<br />

<strong>Heisskanaltechnik</strong><br />

Ch Exist Set Power<br />

1 200° 200° 0%<br />

2 150° 200° 50%<br />

3 0° 300° 100%<br />

4 100° 100° 0%<br />

5 100° 100° 0%<br />

°C/F↓<br />

°C/F↑<br />

CH<br />

CH<br />

1<br />

24V<br />

Bild A<br />

1<br />

Act.<br />

Set<br />

ON<br />

Act.<br />

Set<br />

200 °C<br />

°C<br />

200<br />

Temp.<br />

200 °C<br />

°C<br />

200<br />

24V ON Temp.<br />

Bild B<br />

°C/F↑<br />

CH Act.<br />

200<br />

1 Set<br />

°C<br />

250<br />

24V<br />

Bild C<br />

ON<br />

4 A<br />

Fig. 3-1 Changing a Set Value<br />

The controller operation works independently from the entering of a value. It is therefore not<br />

necessary to return to the scan mode. Scan mode makes exact surveillance of critical regulation<br />

positions possible.<br />

Value limits: The temperatures are adjustable within a range from 0 to 500 °C<br />

(0 to 932 °F).<br />

The percentage control mode is adjustable from 0% to 100%.<br />

3-10<br />