User Manual <strong>Hot</strong> Runner Systems DPK<br />

GÜNTHER<br />

<strong>Hot</strong> Runner Systems<br />

3.6.2 Load Defaults<br />

By selecting the menu item load defaults and affirming the questions with yes twice, the DPK loads<br />

up the parameters and values to the factory settings.<br />

Attention!<br />

All individual entered settings of the DPK (values and parameters) will be<br />

deleted!<br />

The following table shows the default settings:<br />

Set All Channels: 100°C<br />

(all set temperatures)<br />

Temperature Programs: 1. power ON 50%<br />

2. power OFF 75%<br />

3. temp. ON 100°C<br />

4. temp. OFF 200°C<br />

Softstart:<br />

ON<br />

over all time:<br />

hold time:<br />

ramp time:<br />

10min<br />

5min<br />

5min<br />

PID-Parameter: P-Value: 60<br />

(for all channels) I- Value: 60<br />

D- Value: 30<br />

Temperature Unit: °C<br />

Temperature Window: +/- 5°C<br />

Lowering Value: 50°C<br />

Rising Value: 50°C<br />

Language:<br />

Interface:<br />

Heater 5V/24V:<br />

German<br />

Arburg<br />

24V<br />

3-20<br />