Günther Heisskanaltechnik & Heisskanalsysteme, Hot runner
Günther Heisskanaltechnik & Heisskanalsysteme, Hot runner
Günther Heisskanaltechnik & Heisskanalsysteme, Hot runner
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
User Manual <strong>Hot</strong> Runner Systems DPK<br />
GÜNTHER<br />
<strong>Hot</strong> Runner Systems<br />
3.6.2 Load Defaults<br />
By selecting the menu item load defaults and affirming the questions with yes twice, the DPK loads<br />
up the parameters and values to the factory settings.<br />
Attention!<br />
All individual entered settings of the DPK (values and parameters) will be<br />
deleted!<br />
The following table shows the default settings:<br />
Set All Channels: 100°C<br />
(all set temperatures)<br />
Temperature Programs: 1. power ON 50%<br />
2. power OFF 75%<br />
3. temp. ON 100°C<br />
4. temp. OFF 200°C<br />
Softstart:<br />
ON<br />
over all time:<br />
hold time:<br />
ramp time:<br />
10min<br />
5min<br />
5min<br />
PID-Parameter: P-Value: 60<br />
(for all channels) I- Value: 60<br />
D- Value: 30<br />
Temperature Unit: °C<br />
Temperature Window: +/- 5°C<br />
Lowering Value: 50°C<br />
Rising Value: 50°C<br />
Language:<br />
Interface:<br />
Heater 5V/24V:<br />
German<br />
Arburg<br />
24V<br />
3-20<br />
10/99 DPK 1.09