User Manual <strong>Hot</strong> Runner Systems DPK<br />

3.4.3 Changing the Operating Mode „Thermocouple/Percentage“<br />

GÜNTHER<br />

<strong>Hot</strong> Runner Systems<br />

In the event that a thermocouple fails to function, or for any other reason, the percentage control<br />

mode can be carried out to continue the control operation manually. The current will then be<br />

displayed in percent (%).<br />

Mark the menu item power or temp. in single-channel mode by pressing the „"“ key, choose<br />

between thermocouple or percentage by pressing the „#“ or „$“ key.<br />

GÜNTHER<br />

<strong>Heisskanaltechnik</strong><br />

Ch Exist Set Power<br />

1 200° 200° 0%<br />

2 150° 200° 50%<br />

3 0° 300° 100%<br />

4 100° 100° 0%<br />

5 100° 100° 0%<br />

°C/F↓<br />

°C/F↑<br />

CH<br />

CH<br />

1<br />

24V<br />

Bild A<br />

1<br />

24V<br />

Bild B<br />

Act.<br />

Set<br />

ON<br />

Act.<br />

Setl<br />

ON<br />

200 °C<br />

°C<br />

200<br />

Temp.<br />

200 °C<br />

°C<br />

200<br />

Temp.<br />

°C/F↑<br />

CH<br />

Percentage<br />

1 5 %<br />

24V<br />

Bild C<br />

ON<br />

Power<br />

Fig. 3-1 Changing the Operating Mode<br />

For low voltage-nozzles it will be: 100% approximately 125A (for 5V nozzles)<br />

100% approximately 25A (for 24V nozzles)<br />

3-12<br />

10/99 DPK 1.09