User Manual <strong>Hot</strong> Runner Systems DPK<br />
GÜNTHER<br />
<strong>Heisskanaltechnik</strong><br />
Ch 1 error!<br />
thermocouple:<br />
GÜNTHER<br />
<strong>Hot</strong> Runner Systems<br />
Thermocouple Exchange<br />
The thermocouple of the shown channel is not<br />
connected right. The + and – connections are<br />
exchanged. Please change the direction of the<br />
connections.<br />
exchange<br />
- ENTER -<br />
°C/F↓<br />
°C/F↑<br />
Fig. 4-2 Thermocouple Exchange<br />
GÜNTHER<br />
<strong>Heisskanaltechnik</strong><br />
Ch 1 error !<br />
Thermocouple:<br />
Thermocouple Shortcut<br />
There is a short circuit at the thermocouple or its<br />
connections at the shown channel. Please check the<br />
thermocouple and its` wires.<br />
shortcut<br />
- ENTER -<br />
°C/F↓<br />
°C/F↑<br />
Fig. 4-3 Thermocouple Shortcut<br />
GÜNTHER<br />
<strong>Heisskanaltechnik</strong><br />
Ch 1 error!<br />
thermocouple:<br />
Over Temperature<br />
The thermocouple of the shown channel detects a<br />
temperature above 500°C. Please check this<br />
thermocouple and its` wires. You should also check<br />
the thermocouples for neighboring nozzles.<br />
over temperature<br />
- ENTER -<br />
°C/F↓<br />
°C/F↑<br />
Fig. 4-4 Over Temperature<br />