RETAINING CLIPS<br />

Pull off the motor, remove the cover and disconnect<br />

the electrical leads from cable box Figure 40.<br />

Figure 36<br />

CONTROLS FASCIA<br />

N<br />

L<br />

RETAINING CLIPS<br />

CONTROLS CIRCUIT<br />

BOARD COVER<br />

Figure 37<br />

F1 F2<br />

Fit the replacement motor in reverse order ensuring<br />

correct polarity of the electrical connections.<br />

Re-open the isolating valves on the flow and return<br />

connections, refill, vent and re-pressurise the<br />

system and check for leakage.<br />

19.10b Replacing the pump body:<br />

Remove the motor as described above.<br />

Figure 40<br />

Remove the secondary water-to-water heat<br />

exchanger as detailed in (19.12).<br />

26<br />

PRINTED<br />

CIRCUIT<br />

BOARD<br />

Remove the expansion vessel pipe by removing the<br />

clip on the pump body.<br />

Remove the pressure gauge connection<br />

as detailed in (19.11).<br />

19.10 Pump<br />

SCREW<br />

OFF<br />

Figure 38<br />

Disconnect the electrical leads of low pressure<br />

sensor.<br />

Disconnect the pumps outlet fitting.<br />

(Figure 41)<br />

Follow 18.10a or b depending on type of failure.<br />

UNION<br />

NUT<br />

CLIP<br />

19.10a Replacing motor:<br />

Drain the boiler’s hydraulic circuit as detailed in<br />

(19.2).<br />

UNION<br />

NUT<br />

Remove the screws shown in Figure 39.<br />

COVER<br />

ELECTRICAL<br />

CONNECTION<br />

PRESSURE<br />

GAUGE<br />

CONNECTION<br />

PUMP<br />

BODY<br />

Figure 41<br />

Figure 39<br />

EXPANSION<br />

VESSEL<br />

PIPE<br />

SECURING<br />

SCREW<br />

CLIP<br />

PUMP<br />

HEAD<br />

PUMP<br />

BODY<br />

SECURING SCREWS (4 OFF)<br />