20. Gas Type Conversion<br />
Warning<br />
Gas conversion must be carried out by a competent<br />
person as defined in the Gas Safety and Use<br />
Regulations.<br />
If gas type conversion is required (from NG to LPG<br />
etc.), follow the steps below:<br />
The burner must be removed as 18.8 (shown Figure<br />
31.)<br />
Fit the injector bar and tighten, ensuring that the<br />
injector size, marked on each injector is the same<br />
as stated in the relevant section of the ‘Technical<br />
Data’ for the type of gas that will be used.<br />
Fit the burner (replace if necessary) and reassemble<br />
the boiler.<br />
Check for gas soundness.<br />
Dip switch 7 must be ON position for LPG and, OFF for NG.<br />
32<br />
Check the minimum and maximum burner<br />
pressures.<br />
Check the gas circuit for soundness and the correct<br />
operation of the boiler.<br />
Important.<br />
Attach the labels supplied as follows:<br />
Replace the adhesive “User Instruction” label.<br />
Stick the LPG label in a prominent position within the<br />
boiler.<br />
Stick the foil label over the existing gas type on the<br />
data plate of the boiler.<br />
SHOULD YOU SMELL GAS: Turn the gas valve off at the<br />
Gas Meter or Gas Cylinder, ventilate the room by opening<br />
windows and doors (EXTINGUISH ANY NAKED FLAMES,<br />
DO NOT OPERATE ANY ELECTRICAL SWITCHES) and call<br />
Transco on 0800 111 999 or if you use LPG call your gas<br />
supplier.<br />