User’s Manual of <strong>OWON</strong> Colour <strong>Digital</strong> <strong>Storage</strong> <strong>Oscilloscope</strong><br />

How to Set the Trigger System<br />

When the oscilloscope begins to collect the data and display the wave form depends<br />

on a trigger. Once it is set correctly, the trigger can transfer the unstable display into a<br />

meaningful wave form.<br />

When beginning to collect data, the oscilloscope will collect adequate data to draw the<br />

wave form at the left side of the trigger point at first. It will continuously perform the<br />

data acquisition while waiting for the trigger condition. After a trigger is detected, the<br />

oscilloscope will continuously collect data enough to draw the wave form at the right<br />

side of the trigger point.<br />

One knob and four function menu buttons are included in the trigger control zone.<br />

LEVEL: Trigger the level control knob and set the signal voltage corresponding to<br />

the trigger point.<br />

SET TO %50: Set the trigger level as the vertical mid point value of the amplitude of<br />

the trigger signal.<br />

FORCE TRIG: It is a force trigger button for the generation of a trigger signal,<br />

which is mainly used in the “Normal” and "Single” triggering modes.<br />

TRIG VIEW: Trigger the resetting of the horizontal position.<br />

TRIG MENU: It is a trigger menu button. When it is pressed, an operation menu will<br />

be presented in the screen, shown as Fig. 26.<br />

Fig. 26 Trigger Mode Menu<br />