Student Text IAFF Training for Hazardous Materials: Technician©<br />
Corrective Action for Cargo Tank Fittings<br />
Location <strong>of</strong> Leak Probable Cause Basic Repair Methods<br />
VAPOR RECOVERY<br />
VENTS<br />
Liquid leak from vapor<br />
recover line<br />
Top vent not closed<br />
Tank overloaded<br />
Open and re-close top vent<br />
Off-load product*<br />
SAFETY RELIEF<br />
DEVICES<br />
Liquid or vapor leak from<br />
safety vent<br />
Ruptured frangible disk (liquid<br />
indicated possible overload)<br />
Melted fusible plug (liquid indicates<br />
possible overload)<br />
Replace frangible disk; <strong>of</strong>f-load<br />
product if necessary*<br />
Replace fusible plug; <strong>of</strong>f-load<br />
product if necessary*<br />
Liquid or vapor leak from<br />
safety relief valve -- nonpressure<br />
tanks<br />
Defective valve<br />
Tank overloaded<br />
Replace valve<br />
Off-load product*<br />
Liquid or vapor leak from<br />
safety relief valve -- low and<br />
high-pressure tanks<br />
Defective valve<br />
Tank overloaded<br />
To be handled by industry<br />
specialist<br />
To be handled by industry<br />
specialist<br />
*Many leaks can be repaired on loaded, but not overloaded, tanks; <strong>of</strong>f-loading (or transferring) some<br />
or all <strong>of</strong> the product should be performed when the situation dictates.<br />
<strong>Module</strong> 9: <strong>Control</strong> <strong>Techniques</strong> 9-37