IAFF Training for Hazardous Materials: Technician©<br />

Student Text<br />

Sample Line<br />

Liquid or vapor leak Sample line valve not closed Close sample line valve<br />

from sample line orifice<br />

or from around plug Plug missing or loose Replace and/or tighten plug<br />

Thermometer Well<br />

Damaged sample line plug To be handled by a tank car<br />

specialist<br />

Liquid or vapor leak Loose cap with damaged Tighten cap; do not remove<br />

from thermometer well cap thermometer well pipe cap<br />

Missing or defective “O” ring<br />

in cap or on nipple with<br />

damaged thermometer well<br />

pipe<br />

Liquid leaking from Damaged thermometer well To be handled by a tank car<br />

between thermometer well pipe specialist; do not tighten<br />

nipple and manway cover thermometer well nipple<br />

Thermometer well Mechanical damage to To be handled by a tank car<br />

nipple broken <strong>of</strong>f with thermometer well nipple specialist<br />

no leak<br />

Heater Coil-Internal<br />

Corrective Actions for Tank Car Fittings<br />

Miscellaneous Fittings<br />

Location <strong>of</strong> Leak Probable Cause Basic Repair Method<br />

Liquid leak from inlet Condensation from material Tighten caps<br />

or outlet pipes at bottom <strong>of</strong><br />

used for heating contents<br />

tank<br />

Washout<br />

Liquid leaking from around Flange nuts loose Tighten flange nuts<br />

seal between tank and<br />

washout plate Defective gasket To be handled by a tank car<br />

specialist<br />

9-50 <strong>Module</strong> 9: <strong>Control</strong> <strong>Techniques</strong>