18-Nov-2010<br />

<strong>VDX104</strong> <strong>Manual</strong><br />

4.2 IDE Interface (CN2)<br />

The <strong>VDX104</strong> carries an IDE interface compatible with the ATA/ATAPI-6 specification handling up to two<br />

devices, one Master and one Slave (Compact Flash socket included). The interface supports the PIO modes 0<br />

to 4 with flow control, the DMA 0 to 2 and the ultra DMA 0 to 6.<br />

TOP<br />

IDE Interface (CN2)<br />

BOTTOM<br />

Pin # Signal Pin # Signal<br />

1 IDERST# 2 GND<br />

3 IDED7 4 IDED8<br />

5 IDED6 6 IDED9<br />

7 IDED5 8 IDED10<br />

9 IDED4 10 IDED11<br />

11 IDED3 12 IDED12<br />

13 IDED2 14 IDED13<br />

15 IDED1 16 IDED14<br />

17 IDED0 18 IDED15<br />

19 GND 20 NC<br />

21 IDEREQ 22 GND<br />

23 IDEIOW# 24 GND<br />

25 IDEIOR# 26 GND<br />

27 IDERDY 28 GND<br />

29 IDEACK 30 GND<br />

31 IDEIRQ 32 NC<br />

33 IDEA1 34 IDECBLID<br />

35 IDEA0 36 IDEA2<br />

37 IDECS0# 38 IDECS1#<br />

39 IDELED 40 GND<br />

41 +5VDC 42 +5VDC<br />

43 GND 44 NC<br />

Table 3: IDE Interface<br />

<strong>Tri</strong>-M Technologies <strong>Inc</strong>. Tel: 800.665.5600, 604.945.9565<br />

1407 Kebet Way, Unit 100 Fax: 604.945.9566<br />

Port Coquitlam, BC V3C 6L3 E-mail: info@tri-m.com<br />