18-Nov-2010<br />
<strong>VDX104</strong> <strong>Manual</strong><br />
4.7 USB Device Port (CN15) <strong>VDX104</strong>+2E only<br />
The <strong>VDX104</strong>+2E embeds a USB device port connector allowing the unit to be used as a USB device.<br />
USB Device Port (CN15)<br />
Pin #<br />
Signal<br />
1 +5VDC<br />
2 DATA-<br />
3 DATA+<br />
4 NC<br />
5 GND<br />
Table 9: USB Device Port<br />
4.8 Redundancy Port and I 2 C (CN16)<br />
The redundancy port of the <strong>VDX104</strong> provides the communication port and the control signals to interconnect<br />
two CPU boards together. It allows the CPU boards to exchange data and share buses and devices. The<br />
connector also carry an I 2 C bus<br />
Redundancy Port (CN16)<br />
BOTTOM<br />
Pin #<br />
Signal<br />
1 GND<br />
2 I 2 C SCL<br />
3 I 2 C SDA<br />
4 SYS-FAIL-OUT<br />
5 MTBF-OUT<br />
6 GPCS1<br />
7 GPCS0<br />
8 SYS-FAIL-IN<br />
9 SYS-SW-IN<br />
10 SYS-GPCS-IN<br />
11 COM9 TX<br />
12 COM9 RX<br />
13 RESET / PWRGD<br />
Table 8: Redundancy Port<br />
<strong>Tri</strong>-M Technologies <strong>Inc</strong>. Tel: 800.665.5600, 604.945.9565<br />
1407 Kebet Way, Unit 100 Fax: 604.945.9566<br />
Port Coquitlam, BC V3C 6L3 E-mail: info@tri-m.com<br />
Canada Web site: www.tri-m.com 16