CONTROLS & CONNECTIONS<br />
DIVER CONNECTIONS (continued) 5.5<br />
EARPHONE Jack (output) – 4 Wire, (Diver 1, 2 & 3) - This connector is dual 5-Way<br />
Binding Post Jack (color coded black). It is the connection point for the diver’s earphone<br />
when operating in the Simulcom mode (4-wire).<br />
COMMUNICATOR MODEL 2830A-MS (MS CONNECTORS, 5 PIN)<br />
UMBILICAL Connectors - Each diver has one MS Connector. The MS Connector has 5<br />
pins for contacts.<br />
Pin A and Pin B (Input/Output) – Functions as a microphone (input) and as an earphone<br />
(output) when PTT switch is depressed (used in both 2 & 4-wire mode).<br />
In the 2-wire mode <strong>of</strong> operation, microphone is connected into the Umbilical Connector Pin<br />
A & B, also Earphone is connected into Umbilical Connector Pin A & B. Conversation’s<br />
(up-link & down-link) are switched automatically when push to talk switch is actuated.<br />
When a pre-amp microphone is used in the 2-wire mode setup, it is required to have<br />
special speakers supplied only by Amron.<br />
In Simulcom (4-wire) mode, only the diver microphone is connected into umbilical<br />
connector pin A&B.<br />
Pin C and Pin D (Output) – It is the connection point for the diver’s earphone when<br />
operating in the Simulcom mode (4-wire).<br />
Pin E (Earth Ground) – Connected to communicator chassis and ground <strong>of</strong> AC cord.<br />
When communicator AC cord ground pin is contacted to Earth Ground, then Pin E <strong>of</strong> each<br />
diver MS Connector will become Earth Ground.<br />
OTHER CONNECTIONS 5.6<br />
EXTERNAL BATTERY - (Input) - External 12 VDC power input, to operate the unit from an<br />
external battery or power source. Power requirements are 12 volts DC (nominal), not less than 9.5<br />
or more than 18 volts. Source must be able to supply a peak current <strong>of</strong> three amps for proper<br />
operation. With the model /23 Option these jacks are used for charging the internal batteries.<br />
It is highly recommended to use an Amron External Charger, Model 2823-602 as external power<br />
supply. The Amron External Charger was specifically designed for use with all Amron<br />
communicators and has a high degree <strong>of</strong> insulation between the primary and secondary circuits<br />
for diver protection and safety.<br />
WARNING: When using an external power source, it is required to use an insulated DC power<br />
supply that has very low ripple voltage. It has to be properly insulated from AC line for diver<br />
protection and safety. An improperly insulated power supply could cause diver electric shock.<br />
TAPE RECORDER – provides an isolated output, <strong>of</strong> both diver and tender conversations<br />
(balanced), suitable to drive a tape recorder or audio input <strong>of</strong> a VCR. This feature allows recording<br />
<strong>of</strong> conversations between diver and tender.<br />
8