CONTROLS & CONNECTIONS<br />

DIVER CONNECTIONS (continued) 5.5<br />

EARPHONE Jack (output) – 4 Wire, (Diver 1, 2 & 3) - This connector is dual 5-Way<br />

Binding Post Jack (color coded black). It is the connection point for the diver’s earphone<br />

when operating in the Simulcom mode (4-wire).<br />

COMMUNICATOR MODEL 2830A-MS (MS CONNECTORS, 5 PIN)<br />

UMBILICAL Connectors - Each diver has one MS Connector. The MS Connector has 5<br />

pins for contacts.<br />

Pin A and Pin B (Input/Output) – Functions as a microphone (input) and as an earphone<br />

(output) when PTT switch is depressed (used in both 2 & 4-wire mode).<br />

In the 2-wire mode <strong>of</strong> operation, microphone is connected into the Umbilical Connector Pin<br />

A & B, also Earphone is connected into Umbilical Connector Pin A & B. Conversation’s<br />

(up-link & down-link) are switched automatically when push to talk switch is actuated.<br />

When a pre-amp microphone is used in the 2-wire mode setup, it is required to have<br />

special speakers supplied only by Amron.<br />

In Simulcom (4-wire) mode, only the diver microphone is connected into umbilical<br />

connector pin A&B.<br />

Pin C and Pin D (Output) – It is the connection point for the diver’s earphone when<br />

operating in the Simulcom mode (4-wire).<br />

Pin E (Earth Ground) – Connected to communicator chassis and ground <strong>of</strong> AC cord.<br />

When communicator AC cord ground pin is contacted to Earth Ground, then Pin E <strong>of</strong> each<br />

diver MS Connector will become Earth Ground.<br />

OTHER CONNECTIONS 5.6<br />

EXTERNAL BATTERY - (Input) - External 12 VDC power input, to operate the unit from an<br />

external battery or power source. Power requirements are 12 volts DC (nominal), not less than 9.5<br />

or more than 18 volts. Source must be able to supply a peak current <strong>of</strong> three amps for proper<br />

operation. With the model /23 Option these jacks are used for charging the internal batteries.<br />

It is highly recommended to use an Amron External Charger, Model 2823-602 as external power<br />

supply. The Amron External Charger was specifically designed for use with all Amron<br />

communicators and has a high degree <strong>of</strong> insulation between the primary and secondary circuits<br />

for diver protection and safety.<br />

WARNING: When using an external power source, it is required to use an insulated DC power<br />

supply that has very low ripple voltage. It has to be properly insulated from AC line for diver<br />

protection and safety. An improperly insulated power supply could cause diver electric shock.<br />

TAPE RECORDER – provides an isolated output, <strong>of</strong> both diver and tender conversations<br />

(balanced), suitable to drive a tape recorder or audio input <strong>of</strong> a VCR. This feature allows recording<br />

<strong>of</strong> conversations between diver and tender.<br />