<strong>isel</strong>-<strong>CNC</strong> <strong>Machine</strong> CPV<br />

- Enable limit switch (pin 43)<br />

The safety system of the servocontrollers is based on a series circuit of controls, monitoring<br />

and limiting devices, which enables the motor voltage via a safety relay.<br />

If any limit switches are activated due to a misbehaviour of the control system or the<br />

mechanics or due to an operating error, the supply voltage of the output stages is<br />

switched off and remains switched off until the error is eliminated.<br />

In such a case, you must traverse the axes back to the working area prior to any further<br />

machining. To this aim, the operating mode Activate/Deactivate Safety Circuit is provided<br />

in the control system. This function is used to activate the control circuit Enable limit switch<br />

output. This will enable you to restart the power output stages and clear the limit switches<br />

in Teach-in mode.<br />

If you have carried out this action, deactivate the output to return to normal mode.<br />

In this operating mode, observe, in particular, all precautions and safety measures of the<br />

accident prevention rules.<br />

Improper operation of the control unit in this operating state may damage or destroy the<br />

machine!<br />

For additional information on the UPMV 4/12, refer to the UPMV 4/12 Manual<br />