<strong>isel</strong>-<strong>CNC</strong> <strong>Machine</strong> CPV<br />
- Enable limit switch (pin 43)<br />
The safety system of the servocontrollers is based on a series circuit of controls, monitoring<br />
and limiting devices, which enables the motor voltage via a safety relay.<br />
If any limit switches are activated due to a misbehaviour of the control system or the<br />
mechanics or due to an operating error, the supply voltage of the output stages is<br />
switched off and remains switched off until the error is eliminated.<br />
In such a case, you must traverse the axes back to the working area prior to any further<br />
machining. To this aim, the operating mode Activate/Deactivate Safety Circuit is provided<br />
in the control system. This function is used to activate the control circuit Enable limit switch<br />
output. This will enable you to restart the power output stages and clear the limit switches<br />
in Teach-in mode.<br />
If you have carried out this action, deactivate the output to return to normal mode.<br />
In this operating mode, observe, in particular, all precautions and safety measures of the<br />
accident prevention rules.<br />
Improper operation of the control unit in this operating state may damage or destroy the<br />
machine!<br />
For additional information on the UPMV 4/12, refer to the UPMV 4/12 Manual<br />