Chapter 16, Supplementary Regulations for Specific Uses<br />

Unified Development Code of <strong>Forsyth</strong> <strong>County</strong> -16-14-<br />

façade of the building.<br />

(e) All units with front-loaded garages shall have garage faces with decorative design treatments.<br />

(3) Multifamily residences in Res6, CBD, O & I, UV, MPD, and condominiums in Res4:<br />

(a) Exterior walls shall be clad with brick, stone, and/or fiber cement horizontal siding and/or<br />

shakes/shingles. No more than twenty percent (20%) shall include accent wall materials such<br />

as exterior finish insulation systems, stucco and painted dimension wood.<br />

(b) The primary material on the front elevation shall also be used on the side and rear elevations.<br />

There shall be a combination of no less than two (2) of the above listed materials on each<br />

façade of the building.<br />

(c) Heating, cooling, kitchen and other mechanical equipment; conduits, service panels, meters<br />

and other electrical equipment; and refuse collection facilities shall be located and/or screened<br />

so as not to be visible from adjacent development and/or the street.<br />

(d) A minimum exterior setback of fifty feet (50’), the first twenty-five feet (25’) being an<br />

exterior buffer, shall be required in CBD, O & I, UV, and MPD zoning districts, The exterior<br />

buffer shall meet <strong>Forsyth</strong> <strong>County</strong> Buffer Standards, but such requirement shall be exempted<br />

along the entire road frontage on which the primary entrance is located.<br />

(4) Residential facilities (assisted living and/or skilled nursing) in Res4, Res6, CBD, O & I, UV, and<br />

MPD:<br />

(a) Exterior walls shall be clad with brick, stone, and/or fiber cement horizontal siding and/or<br />

shakes/shingles. No more than twenty-five percent (25%) shall include accent wall materials<br />

such as exterior finish insulation systems, stucco, and painted dimension wood.<br />

(b) The primary material on the front elevation shall also be used on the side and rear elevations.<br />

There shall be a combination of no less than two (2) of the above listed materials on each<br />

façade of the building.<br />

(c) Freestanding accessory structures shall have architectural detailing and design elements<br />

consistent with the primary building(s) of the development complex to provide a cohesive<br />

design.<br />

(d) Heating, cooling, kitchen and other mechanical equipment; conduits, service panels, meters<br />

and other electrical equipment; and refuse collection facilities shall be located and/or screened<br />

so as not to be visible from adjacent development and/or the street.<br />

(e) A minimum exterior setback of fifty feet (50’), the first twenty-five feet (25’) being an exterior<br />

buffer, shall be required in CBD, O & I, UV, and MPD zoning districts, The exterior buffer<br />

shall meet <strong>Forsyth</strong> <strong>County</strong> Buffer Standards, but such requirement shall be exempted along the<br />

entire road frontage on which the primary entrance is located.<br />

(F) Parking. Senior housing parking requirements in all districts:<br />

(1) The required number of parking stalls is one per senior housing unit including rooms within<br />

assisted living and skilled nursing facilities. Garages for detached housing units will be<br />

considered as satisfying the parking stall requirement. This may be reduced to one stall per one and<br />

one-half dwelling units if justification for the reduction can be provided based on the number and<br />

types of services and activities to be provided on-site or other factors which affect parking demand.<br />

(G) Density Bonus Options. Density may be increased where a density range is shown in Table 16.3.<br />

Density bonus options shall be approved by the Board of Commissioners as part of the conditional use<br />

permit (CUP) application process. These options are outlined in Table 16.4.<br />

TABLE 16.4 DENSITY BONUS TABLE<br />

Zoning District<br />

CBD O & I UV MPD<br />

Base Density* 10 10 10 10<br />

Assisted Living Units<br />

(5-19%)**<br />

+2 +2 +2 +2<br />

Assisted Living Units<br />

(20%)**<br />

Assisted Living Units<br />

(20-29%)**<br />

+3 +3 +3 +3<br />

+3 +3 +3 +3