windows varies throughout the country. It could be as much as 20% of<br />

the floor area in sunny cold climates, where advanced glozings or<br />

moveable insulation ore recommended to prevent heat loss at night.<br />

These buildings hove high insulation levels <strong>and</strong> added thermal moss<br />

for heat storage.<br />

PROJECTED AREA The net south-facing glozing area projected on a<br />

vertical plane.<br />

SUN TEMPERING A sun-tempered building is elongated in the<br />

east-west direction, with the majority of the windows on the south side.<br />

The area of the windows is general hmited to about 7% of the total<br />

floor area. A sun-tempered design has no added thermal moss beyond<br />

what is already in the framing, wall board, <strong>and</strong> so on. Insulation levek<br />

ore generally high.<br />

THERMAL STORAGE WALLS (MASONRY OR WATER) Athermal<br />

storage wall is a south-facing wall that is glozed on the outside.<br />

Solar heat strikes the glozing <strong>and</strong> is absorbed into the wall, which<br />

conducls the heat into the room over time. The walls ore at least 8 in<br />

thick. General, the thicker the woll, the less the indoor temperature<br />

fluctuates .<br />

• APPLICABILITY<br />

FAOUTY TYPE Primarily new residential construction. Because most<br />

passive solar design components ore on integral port of the building,<br />

application is best suited to new construction. Retrofiffing is generally<br />

limited to adding a greenhouse or a sunspoce.<br />

CUMATE Passive solar design is applicable to all dimate zones. The<br />

optimal passive solar system size varies by locotion <strong>and</strong> is shown in<br />

Figure R-29. Figures R-30, R-31, <strong>and</strong> R-32 show the annual savings<br />

from solar for different system types. The sizes ore based on the<br />

assumption that the building is well-insulated.<br />

DEMAND-SIDE MANAGEMENT STRATEGY Strategic conservation,<br />

lood shifting.<br />