Service Manual PLATINUM ENG.pdf
Service Manual PLATINUM ENG.pdf
Service Manual PLATINUM ENG.pdf
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Ideas with Passion<br />
6.4 Aqua Prima<br />
Operating logic with “AQUA PRIMA” filter.<br />
When use of the “aqua prima” filter is selected on the user menu or via the control panel, the<br />
system water count logic is as follows:<br />
If the “aqua prima” function is enabled the electronics perform a pulse count of the turbine,<br />
recording one pulse every 2 revolutions.<br />
If the “aqua prima” function is disabled, the electronics perform a pulse count of the turbine,<br />
recording one pulse every revolution.<br />
The graph in the figure below illustrates this function:<br />
Aqua Prima<br />
on<br />
Aqua Prima<br />
off<br />
Turbine revs<br />
360°<br />
1 rev<br />
360°<br />
1 rev<br />
360°<br />
1 rev<br />
360°<br />
1 rev<br />
= 1 pulse<br />
TALEA Section 06<br />
REV00 - August 06<br />
3/6