Ideas with Passion<br />

6.4 Aqua Prima<br />

Operating logic with “AQUA PRIMA” filter.<br />

When use of the “aqua prima” filter is selected on the user menu or via the control panel, the<br />

system water count logic is as follows:<br />

If the “aqua prima” function is enabled the electronics perform a pulse count of the turbine,<br />

recording one pulse every 2 revolutions.<br />

If the “aqua prima” function is disabled, the electronics perform a pulse count of the turbine,<br />

recording one pulse every revolution.<br />

The graph in the figure below illustrates this function:<br />

Aqua Prima<br />

on<br />

Aqua Prima<br />

off<br />

Turbine revs<br />

360°<br />

1 rev<br />

360°<br />

1 rev<br />

360°<br />

1 rev<br />

360°<br />

1 rev<br />

= 1 pulse<br />

TALEA Section 06<br />

REV00 - August 06<br />