gab.ru Берг АБ bergab@ya.ru Тел. (495)-228-06-21,<br />

<strong>Industrial</strong><br />

факс<br />

<strong>shaft</strong> <strong>seals</strong><br />

(495) 22<br />

Cover plates<br />

All HS type <strong>seals</strong>, split and solid are 0,4 to 0,8<br />

mm (0.016 to 0.031 in) wider than the bore<br />

depth and have outside diameters that are 2 %<br />

to 5 % larger than the seal housing bore. The<br />

end user is required to fabricate and use a<br />

cover plate for proper fit. The cover plate<br />

provides axial compression and supplements<br />

radial press fit to ensure maximum seal<br />

performance. It should be thick enough not to<br />

bend or distort. Generally, a thickness of 6,35<br />

to 12,7 mm (0.250 to 0.500 in) is sufficient.<br />

The plate should be secured with bolts, no<br />

more than 150 mm (6 in) apart, on a bolt<br />

circle located as close to the seal housing bore<br />

as practical. The cover plate should be flat and<br />

the housing bore depth uniform. Splitting the<br />

cover plate at 180° will make seal replacement<br />

easier, particularly in confined areas.<br />

To block surges of lubricant towards the seal<br />

from the inside and to protect the seal from<br />

damage from the outside, it is recommended<br />

that the cover plate inner diameter be as close<br />

as practical to the <strong>shaft</strong>. Generally, 6,35 mm<br />

(0.250 in) over <strong>shaft</strong> diameter is sufficient in<br />

the presence of <strong>shaft</strong> misalignment and run<br />

out.<br />

Sometimes, supplementary sealing needs to<br />

be added. It is impractical to machine the<br />

original housing to provide the seal cavity<br />

required. In such instances, the seal cavity may<br />

be incorporated into a new plate, which is<br />

bolted into place as illustrated (fig 66).<br />

New seal cavity plate<br />

Seal<br />

retaining<br />

cover plate<br />

6,35 mm<br />

(0,250 in)<br />

Sealing element<br />

Fig 66<br />