Table 17 shows that for one collector meter plus multiple smart meters, peak<br />

power limit violations are predicted to occur at 60% @ 40% to 100% and<br />

100% reflection @ 30% to 100% duty cycles. At 1000% and 2000%<br />

reflection factors, peak power limit violations are predicted at all duty<br />

cycles.<br />

Where are RF levels associated with inhibition of DNA repair in human<br />

stem cells at 92.5 uW/cm2 exceeded the in the nursery crib at 11” distance?<br />

Table 18 shows that for one smart meter, RF exposures associated with<br />

inhibition of DNA repair in human stem cells are predicted to occur at 60%<br />

reflection factor@ 70% to 100% duty cycles, and at 100% reflection factor<br />

@ 50% to 100% duty cycles. All scenarios using either 1000% or 2000%<br />

reflection factors exceed these RF exposures except 1000% at 1% duty<br />

cycle.<br />

Table 18 also shows that for multiple smart meters, RF exposures associated<br />

with inhibition of DNA repair in human stem cells are predicted to occur at<br />

60% reflection factor@ 20% to 100% duty cycles, and at 100% reflection<br />

factor @ 20% to 100% duty cycles. All scenarios using either 1000% or<br />

2000% reflection factors exceed these RF exposure levels except 1000% at<br />

1% duty cycle.<br />

Table 19 shows that for one collector meter, RF exposures associated with<br />

inhibition of DNA repair in human stem cells are predicted to occur at 60%<br />

reflection factor@ 30% to 100% duty cycles, and at 100% reflection factor<br />

@ 20% to 100% duty cycles. All scenarios using either 1000% or 2000%<br />

reflection factors exceed these RF exposure levels.<br />

Table 19 shows that for one collector meter plus multiple smart meters, RF<br />

exposures associated with inhibition of DNA repair in human stem cells are<br />

predicted to occur at 60% reflection factor@ 20% to 100% duty cycles, and<br />

at 100% reflection factor @ 10% to 100% duty cycles. All scenarios using<br />

either 1000% or 2000% reflection factors exceed these RF exposure levels.<br />

Where are RF levels associated with pathological leakage of the blood-brain<br />

barrier at 0.4 – 8 uW/cm2 exceeded the in the nursery crib at 11” distance?