02.06.2014 Views

Smart Meters - Public Service Commission

Smart Meters - Public Service Commission

Smart Meters - Public Service Commission

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Table 20 shows that for one smart meter, RF exposures associated with<br />

pathological leakage of the blood-brain barrier at 8 uW/cm2 are predicted to<br />

occur at 60% reflection factor@ 10% to 100% duty cycles, and at 100%<br />

reflection factor @ 5% to 100% duty cycles. RF levels at 0.4 uW/cm2 (the<br />

lower end of the range) are exceeded at all duty cycles and at all reflection<br />

factors in the nursery in the crib.<br />

Table 20 also shows that for multiple smart meters, RF exposures associated<br />

with pathological leakage of the blood-brain barrier at 8 uW/cm2 are<br />

predicted to occur at 60% reflection factor@ 5% to 100% duty cycles, and at<br />

100% reflection factor @ 5% to 100% duty cycles. RF levels at 0.4<br />

uW/cm2 (the lower end of the range) are exceeded at all duty cycles and at<br />

all reflection factors in the nursery in the crib.<br />

Table 21 shows that for one collector meter, RF exposures associated with<br />

pathological leakage of the blood-brain barrier at 8 uW/cm2 are predicted to<br />

occur at 60% reflection factor@ 5% to 100% duty cycles, and at 100%<br />

reflection factor @ 5% to 100% duty cycles. RF levels at 0.4 uW/cm2 (the<br />

lower end of the range) are exceeded at all duty cycles and at all reflection<br />

factors in the nursery in the crib.<br />

Table 21 shows that for one collector meter plus multiple smart meters, .RF<br />

exposures associated with pathological leakage of the blood-brain barrier at<br />

8 uW/cm2 are predicted to occur at 60% reflection factor@ 5% to 100%<br />

duty cycles, and at 100% reflection factor @ 1% to 100% duty cycles. RF<br />

levels at 0.4 uW/cm2 (the lower end of the range) are exceeded at all duty<br />

cycles and at all reflection factors in the nursery in the crib.<br />

Where are RF levels associated with adverse neurological symptoms,<br />

cardiac problems and increased cancer risk exceeded in the nursery crib at<br />

11” distance?<br />

Table 22 shows that for one smart meter, RF exposures associated with<br />

adverse neurological symptoms above 0.1 uW/cm2 are exceeded at all duty<br />

cycles and at all reflection factors in the nursery in the crib.<br />

Table 22 shows that for multiple smart meters, RF exposures associated with<br />

adverse neurological symptoms above 0.1 uW/cm2 are exceeded at all duty

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!