02.06.2014 Views

Smart Meters - Public Service Commission

Smart Meters - Public Service Commission

Smart Meters - Public Service Commission

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Where are RF levels associated with pathological leakage of the blood-brain<br />

barrier and neuron death at 0.4 – 8 uW/cm2 risk in the kitchen work space<br />

at 28” distance?<br />

Table 26 shows that for one smart meter, RF exposures associated with<br />

pathological leakage of the blood-brain barrier at 8 uW/cm2 are predicted to<br />

occur at 60% reflection factor@ 40% to 100% duty cycles, and at 100%<br />

reflection factor @ 30% to 100% duty cycles, and at all 1000% and 2000%<br />

reflections. RF levels at 0.4 uW/cm2 (the lower end of the range) are<br />

exceeded at all duty cycles and at all reflection factors in the kitchen work<br />

space except at 1% duty cycle for 60% and 100% reflections.<br />

Table 26 also shows that for multiple smart meters, RF exposures associated<br />

with pathological leakage of the blood-brain barrier at 8 uW/cm2 are<br />

predicted to occur at 60% reflection factor@ 30% to 100% duty cycles, and<br />

at 100% reflection factor @ 20% to 100% duty cycles, and at all 1000% and<br />

2000% reflections. RF levels at 0.4 uW/cm2 (the lower end of the range)<br />

are exceeded at all duty cycles and at all reflection factors in the kitchen.<br />

Table 27 shows that for one collector meter, RF exposures associated with<br />

pathological leakage of the blood-brain barrier at 8 uW/cm2 are predicted to<br />

occur at 60% reflection factor@ 20% to 100% duty cycles, and at 100%<br />

reflection factor @ 10% to 100% duty cycles. RF levels at 0.4 uW/cm2 (the<br />

lower end of the range) are exceeded at all duty cycles and at all reflection<br />

factors in the kitchen work space.<br />

Table 27 shows that for one collector meter plus multiple smart meters, .RF<br />

exposures associated with pathological leakage of the blood-brain barrier at<br />

8 uW/cm2 are predicted to occur at 60% reflection factor@ 20% to 100%<br />

duty cycles, and at 100% reflection factor @ 20% to 100% duty cycles. RF<br />

levels at 0.4 uW/cm2 (the lower end of the range) are exceeded at all duty<br />

cycles and at all reflection factors in the kitchen work space.<br />

Where are RF levels associated with adverse neurological symptoms,<br />

cardiac problems and increased cancer risk in the kitchen work space at<br />

28” distance?<br />

Table 28 shows that for one smart meter, RF exposures associated with

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!