02.06.2014 Views

Smart Meters - Public Service Commission

Smart Meters - Public Service Commission

Smart Meters - Public Service Commission

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

cycles and at all reflection factors in the nursery in the crib.<br />

Table 23 shows that for one collector meter, RF exposures associated with<br />

adverse neurological symptoms above 0.1 uW/cm2 are exceeded at all duty<br />

cycles and at all reflection factors in the nursery in the crib.<br />

Table 23 shows that for one collector meter plus multiple smart meterss, RF<br />

exposures associated with adverse neurological symptoms above 0.1<br />

uW/cm2 are exceeded at all duty cycles and at all reflection factors in the<br />

nursery in the crib.<br />

Where are RF levels associated with inhibition of DNA repair in human<br />

stem cells at 92.5 uW/cm2 exceeded the in the kitchen work space at 28”<br />

distance?<br />

Table 24 shows that for one smart meter, RF levels do not exceed those<br />

associated with inhibition of DNA repair at 60% or 100% reflection factor at<br />

any duty cycle. RF levels are exceeded at 1000% @ 10% to 100% duty<br />

cycles; and at 2000% reflection factor @ 5% to 100% duty cycles.<br />

Table 24 also shows that for multiple smart meters, RF levels do not exceed<br />

those associated with inhibition of DNA repair at 60% or 100% reflection<br />

factor at any duty cycle. RF levels are exceeded at 1000% @ 5% to 100%<br />

duty cycles; and at 2000% reflection factor @ 1% to 100% duty cycles.<br />

Table 25 shows that for one collector meter, RF levels do not exceed those<br />

associated with inhibition of DNA repair at 60% at any duty cycle; at 100%<br />

reflection factor they are exceeded at 70% to 100% duty cycles.. RF levels<br />

are exceeded at 1000% @ 5% to 100% duty cycles; and at 2000% reflection<br />

factor @ 1% to 100% duty cycles.<br />

Table 25 shows that for one collector meter plus multiple smart meters, RF<br />

levels exceed those associated with inhibition of DNA repair at 60%<br />

reflection@100% duty cycle; at 100% reflection factor they are exceeded at<br />

70% to 100% duty cycles.. RF levels are exceeded at 1000% @ 5% to<br />

100% duty cycles; and at 2000% reflection factor @ 1% to 100% duty<br />

cycles.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!