CentreCOM 3600 Series Hub/Repeaters<br />

10BASE2 Wiring Specifications<br />

10BASE2 (or thinnet) requires a thin coaxial cable, RG58. RG58 is a<br />

10 MHz, baseband cable connected with BNC-series connectors. The cable<br />

must be terminated with 50 Ω terminators and grounded at one end.<br />

Maximum segment length is 185 meters (606 ft.).<br />

Thinnet coaxial cable is plugged directly into the BNC receptacle for Ports<br />

1 through 8. Next to each of these ports is a 50 Ω termination switch. If<br />

you install a BNC-T connector with a 50 Ω resistor like the one shown in<br />

Figure 32, you must disable the ports’ internal termination by turning the<br />

switch OFF).<br />

Figure 32: BNC-T at End of<br />

10BASE2 Segment<br />

If you install a coaxial cable segment without a BNC-T connector at the<br />

end (as shown in Figure 33), you must enable the internal termination of<br />

the port by turning the 50 Ω termination switch ON.<br />

Figure 33: BNC Connector<br />

33