CentreCOM 3600 Series Hub/Repeaters<br />
10BASE2 Wiring Specifications<br />
10BASE2 (or thinnet) requires a thin coaxial cable, RG58. RG58 is a<br />
10 MHz, baseband cable connected with BNC-series connectors. The cable<br />
must be terminated with 50 Ω terminators and grounded at one end.<br />
Maximum segment length is 185 meters (606 ft.).<br />
Thinnet coaxial cable is plugged directly into the BNC receptacle for Ports<br />
1 through 8. Next to each of these ports is a 50 Ω termination switch. If<br />
you install a BNC-T connector with a 50 Ω resistor like the one shown in<br />
Figure 32, you must disable the ports’ internal termination by turning the<br />
switch OFF).<br />
Figure 32: BNC-T at End of<br />
10BASE2 Segment<br />
If you install a coaxial cable segment without a BNC-T connector at the<br />
end (as shown in Figure 33), you must enable the internal termination of<br />
the port by turning the 50 Ω termination switch ON.<br />
Figure 33: BNC Connector<br />