CentreCOM 3600 Series Hub/Repeaters<br />
UTP MAU-to-MAU,<br />
Hub-to-Hub Wiring<br />
10BASE-T MAU-to-MAU or hub-to-hub wiring generally requires a<br />
crossover cable located somewhere along the UTP cable run. This may<br />
commonly occur at the punch-down block or between the RJ45 wall<br />
receptacle and the workstation. See Figure 49.<br />
TD+<br />
RJ 45 Pin<br />
1<br />
1<br />
RJ 45 Pin<br />
1<br />
TD+<br />
TD-<br />
2<br />
2<br />
TD-<br />
RD+<br />
Not Used<br />
3<br />
4<br />
1<br />
3<br />
4<br />
RD+<br />
Not Used<br />
Not Used<br />
5<br />
5<br />
Not Used<br />
RD-<br />
6<br />
6<br />
RD-<br />
Figure 49: Hub-to-Hub or<br />
MAU-to-MAU<br />
Wiring<br />
Not Used<br />
Not Used<br />
7<br />
8<br />
1 Pair twisted as per level 3, 4 or 5 cable<br />
7<br />
8<br />
Not Used<br />
Not Used<br />