Appendix A<br />

UTP Reference<br />

UTP Wiring Specifications<br />

10BASE-T requires UTP wiring capable of supporting 10 Megabit data rates.<br />

Use Level 3 or better UTP wiring throughout the 10BASE-T wiring system.<br />

The wire should be 22 to 26 AWG, 100 Ω impedance with 3 to 8 twists per foot.<br />

Typically, if a cable is flat, the pairs are untwisted and will cause problems. A<br />

cable more or less round in section is likely to be twisted.<br />

The specifications of 6 common modular cables and their applicability to<br />

10BASE-T network use are shown in Table 5. The maximum length for<br />

10BASE-T UTP segments is 100 meters (328 ft.).<br />

Table 5: Usable and Unusable Twisted Pair Cable<br />

Cable<br />

Level<br />

Cable Description AC Character Specification<br />

Twist/<br />

Foot<br />

10BASE-T<br />

OK?<br />

1 Unshielded untwisted N/A CCITT N/A NO!<br />

2 Individual UTP 100 Ω ± 30 Ω RS232 1BASE5<br />

<strong>AT</strong>&T PDS<br />

N/A<br />

NO!<br />

3 Typical Individual UTP 100 Ω ± 15 Ω TI, <strong>AT</strong>&T ISDN<br />

10BASE-T<br />

IBM Type 3<br />

4 Enhanced Individual UTP 100 Ω ± 30 Ω EIA, TIA<br />

10BASE-T<br />

NEMA<br />

5 Individual STP 100 Ω ± 30 Ω EIA, TIA<br />

10BASE-T<br />

3-5 YES<br />

5-8 YES<br />

8-10 YES<br />

IBM<br />

Type 1<br />

Individual STP 150 Ω PCC FT 1 N/A NO!<br />