11.06.2014 Views

RTS200 RFID Test Set - RFID Webshop

RTS200 RFID Test Set - RFID Webshop

RTS200 RFID Test Set - RFID Webshop

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The test suite structure is described in the tree on the left of the screen. The root of the tree is the<br />

test suite (Read_Data_ISO15693 in the example), while the branches correspond to individual<br />

tests (Read Tag Data, Resonant Frequency and Q Factor in the example).<br />

There is also a machine interface configuration file, which includes all the information needed for<br />

the <strong>RTS200</strong> to interface with the machine where it is operating. Parameters defining the hardware<br />

signals used to control the operation, time characteristics …<br />

Selecting an item on the tree (the test suite or an individual test), makes it possible to see in the<br />

right side of the window the properties associated with the element. There are three different types<br />

of properties. They can be seen selecting the corresponding tab page on the screen.<br />

Property Type<br />

Identification<br />

<strong>Test</strong> Conditions<br />

<strong>Test</strong> Limits<br />

Explanation<br />

The name, date, comments, ... corresponding to the test suite or individual test are defined here. The<br />

parameter name and number are open, so the user can add as many identificative properties as<br />

needed.<br />

The conditions of the test are described here. This corresponds to values needed for some operating<br />

parameters. For instance, the RX frequency, the number of samples to take, ... The conditions also<br />

correspond to configuration parameters on the Tag Analyzer screen.<br />

These are the limits to consider a test result to be valid or not. When the test result falls between the<br />

limits, a PASS indication appear in Tag Analyzer mode, and the result is considered valid in Online<br />

mode. Other parameters defined here are used to control the appearance of the data results in the<br />

online test screen.<br />

The <strong>Test</strong> conditions and <strong>Test</strong> limits have special Keywords for the parameters. The keywords can<br />

not be changed. ANNEX 2 describes those pre-defined keywords. More keywords can be added in<br />

the future if more parameters have to be changed for different tests.<br />

Pag: 25 Document: <strong>RTS200</strong> <strong>RFID</strong> <strong>Test</strong> <strong>Set</strong> Code: 001.0036 Version: 1