Register Description<br />

The Advanced Watchdog Timer has a Setup Register and a Runtime Register. The Setup Register is set by the<br />

BIOS, and can be adjusted by entering the BIOS Setup Utility, and going to “Advanced/Miscellaneous<br />

Configuration”. The Setup Register may also be read by the driver to determine if the Watchdog is enabled, and<br />

the interrupt and base address that it is using.<br />

Note Enabling the watchdog timer in the BIOS does not actually arm it. The watchdog timer can be<br />

armed by accessing I/O address 465h, as explained below.<br />

Table 50<br />

Advanced Watchdog Setup Register 46Dh<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

Reserved<br />

WDT_IRQ<br />

Select Interrupt for WDT<br />

000=Disabled<br />

001 = IRQ5<br />

010 = IRQ7<br />

011 = IRQ10<br />

100 = IRQ11<br />

101 = IRQ12<br />

110 = IRQ3<br />

111 = IRQ6<br />

Reg_Enable<br />

0=Watchdog timer is disabled and<br />

Runtime Register will not appear<br />

in I/O map<br />

1=Watchdog Timer is enabled.<br />

Runtime Register will appear in<br />

I/O map<br />

Table 51<br />

Advanced Watchdog Runtime Register 465h<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

WDT_Active<br />

0=Watchdog<br />

timer is<br />

disabled.<br />

1=Watchdog is<br />

armed and<br />

can generate<br />

resets and<br />

interrupts.<br />

WDT_IRQ_Ena<br />

0=Watchdog<br />

interrupt is<br />

disabled.<br />

1=Watchdog<br />

interrupt is<br />

enabled.<br />

Reserved<br />

WDT_IRQ_Time<br />

Select Interrupt<br />

time for<br />

WDT<br />

00=0.25s<br />

01 = 0.50s<br />

10 = 0.75s<br />

11 = 1.00s<br />

WDT_RST_Time<br />

Select Reset time<br />

for WDT<br />

00=1.55-2.10s<br />

01 = 0.50s<br />

10 = 0.75s<br />

11 = 1.00s<br />

Reading the Runtime Register also refreshes the watchdog timer.<br />