Terminal connection diagram of wall mounted assembly<br />

Potentiostatic electrode, Type PM-J (see terminal connection diagram at the top)<br />

Amperometric electrode (see terminal connection diagram at the bottom)<br />

Temperature<br />

Pt 100<br />

Relay 1 Relay 2 Relay 3<br />

Power<br />

Temperature<br />

Pt 100<br />

Relay 1 Relay 2 Relay 3<br />

Power<br />

26<br />

27<br />

28<br />

29<br />

30<br />

31<br />

32<br />

33<br />

35<br />

36<br />

37<br />

38<br />

39<br />

40<br />

41<br />

42<br />

43<br />

44<br />

45<br />

46<br />

44<br />

45<br />

46<br />

26<br />

27<br />

28<br />

29<br />

30<br />

31<br />

32<br />

33<br />

35<br />

36<br />

37<br />

Measurement / gold electrode (violet)<br />

Reference electrode with cable (black)<br />

Counter electrode / stainless steel electrode (red)<br />

38<br />

39<br />

40<br />

41<br />

42<br />

43<br />

44<br />

45<br />

46<br />

44<br />

45<br />

46<br />

Potentiostatic<br />

electrode<br />

shielding reference electrode<br />

pH<br />

internal lead electrode<br />

GND<br />

GND<br />

GND<br />

GND<br />

GND<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

-<br />

+<br />

Analog output 1<br />

0/4 - 20 mA<br />

-<br />

+<br />

Analog output 2<br />

0/4 - 20 mA<br />

-<br />

+<br />

Analog output 3<br />

0/4 - 20 mA<br />

GND<br />

RS 485<br />

(Optional)<br />

GND<br />

GND<br />

34<br />

- +<br />

<strong>TOPAX</strong> <strong>DE</strong> 4: REDOX, 35 = internal lead<br />

<strong>TOPAX</strong> <strong>DE</strong> 3/6: disturbance variable 0/4 - 20mA, 34 = -, 35 = +<br />

-<br />

+<br />

Water deficiency<br />

L<br />

N<br />

PE<br />

23<br />

24<br />

25<br />

- +<br />

GND<br />

GND<br />

34<br />

-<br />

+<br />

L<br />

N<br />

PE<br />

Measuring electrode (red)<br />

Copper (blue) or silver (violet) electrode<br />

shielding reference electrode<br />

internal lead electrode<br />

pH<br />

Amperometrische<br />

Messzelle<br />

GND<br />

GND<br />

GND<br />

GND<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

-<br />

+<br />

Analog output 1<br />

0/4 - 20 mA<br />

-<br />

+<br />

Analog output 2<br />

0/4 - 20 mA<br />

-<br />

+<br />

GND<br />

RS 485<br />

(Optional)<br />

GND<br />

GND<br />

Water deficiency<br />

23<br />

24<br />

25<br />

Analog output 3<br />

0/4 - 20 mA<br />

- +<br />

GND<br />

<strong>TOPAX</strong> <strong>DE</strong> 4: REDOX, 35 = internal lead<br />

<strong>TOPAX</strong> <strong>DE</strong> 3/6: disturbance variable 0/4 - 20mA, 34 = -, 35 = +<br />

- +<br />

18 | Operating Manual <strong>TOPAX</strong> <strong>DE</strong> | Device Installation and Connection