4.4.5.15<br />
1. Parameters and Options: Parameters are depicted in both the ASCII and<br />
hexadecimal representations as the letter 'P' followed by a lower-case<br />
character or number. These are interpreted as follows:<br />
Pn: Value parameter, to be replaced by a value, using one ASCII<br />
character per digit without leading zeros.<br />
P1: Ordered and numbered parameter. One <strong>of</strong> a listed known<br />
parameters with a specified order and number (Continues<br />
with P2, P3, etc.)<br />
Px: Display column number (1-40), using one ASCII character per<br />
digit without leading zero.<br />
Py: Display line (1-4) one ASCII character<br />
...: Continue the list in the same fashion<br />
Values <strong>of</strong> 'h' (0x68) and 'l' (0x6C) are used to indicate binary operations. 'h'<br />
represents ON (high), 'l' represents OFF (low).<br />
2. ASCII Representation: Individual characters are separated by spaces; these<br />
are not to be interpreted as the space character, which is depicted by SPC.<br />
3. Hexadecimal Representation: Characters are shown as their hexadecimal<br />
values and will be in the range 0x00 to 0x7F (7 bits).<br />
The <strong>Controller</strong> Circuit shall communicate via a SP6 asynchronous serial interface. The<br />
interface shall be configured for 38.4 Kbps, 8 data bits, 1 stop bit, and no parity.<br />
4.4.5.16<br />
C50 ENABLE function when grounded by pins 1 and 5, shall be brought to Connectors<br />
A1, pin B21 for the purpose <strong>of</strong> disabling the module channel 2, (SP4).<br />
4.4.6 Electronic Bell<br />
The Front Panel shall include an electronic bell to signal receipt <strong>of</strong> (0x07). The bell shall<br />
sound at 2,000 Hz, with a minimum output rating <strong>of</strong> 85 dB upon receipt <strong>of</strong> (0x07).<br />
Receipt <strong>of</strong> all other characters and ESC codes shall continue during the time the bell<br />
sounds.<br />
4.5 Type 2070-4 Power Supply Module<br />
4.5.1 General<br />
The Type 2070-4 Power Supply Module shall be independent, self contained Module,<br />
vented, and cooled by convection only. The Module shall slide into the unit’s power<br />
Standard for the ATC – Type 2070 March 29, 2001<br />
66