CPU / FCU operation at POWER UP shall be as follows:<br />

5.4.2.11.7<br />

1. FCU Comm Loss Flag set. FAULT and VOLTAGE MONITOR outputs<br />

set to FALSE state.<br />

2. CPU REQUEST MODULE STATUS COMMAND Message with “E” bit<br />

set is sent to FCU to clear Comm Loss Flag and responses to CPU with<br />

“E” bit set.<br />

3. Before the Comm Loss timer expires, the SET OUTPUT COMMAND<br />

data must be sent. In that data, the 078 and 079 logically set to “0” will<br />

cause the FCU microprocessor port pins assigned for FM and VM outputs<br />

to go to their TRUE state. At this point, the signal outputs defined in the<br />

message will be permitted at the output connectors. Any number <strong>of</strong> other<br />

messages may be sent between the MODULE STATUS COMMAND and<br />

SET OUTPUTS COMMAND.<br />

4. If the above message sequence is not followed, Comm Loss Flag shall be<br />

set (or remain) and VM & FM shall retain the FALSE output state.<br />

5. This is operational and preceded User S<strong>of</strong>tware.<br />

A CPU / FCU Communications Loss during normal operation shall cause all outputs to<br />

go blank (FALSE state) and shall set the Comm Loss Flag. FM and VM outputs shall be<br />

in FALSE state.<br />

5.4.3 Type 2070N Back Cover<br />

The 2070N Back Cover shall be provided to protect the interface harnesses. The Back<br />

Cover shall be delivered attached to the 2070 ATMS <strong>Controller</strong> Unit and 2070-8 NEMA<br />

Interface Module per Section 5.<br />

5.5 Chapter Details<br />

TABLE OF CONTENTS<br />

Type 2070-6 - Async/Modem Serial Comm Module 5-5-1<br />

Type 2070-7 - Serial Comm Module 5-5-2<br />

Type 2070N - NEMA Module, Front View 5-5-3<br />

Type 2070N - NEMA Module, Side View 5-5-4<br />

Type 2070N - NEMA Module, Isometric View 5-5-5<br />

Standard for the ATC – Type 2070 March 29, 2001<br />

92