TYPICAL AIR INTAKE PIPE CONNECTIONS<br />

UPFLOW DIRECT VENT APPLICATIONS<br />

(Right−Hand Exit Shown)<br />

2−1/2",<br />

3" OR<br />

4<br />

2<br />

TRANSITION<br />

2*<br />

TRANSITION<br />

2−1/2",<br />

3" OR<br />

4<br />

2<br />

2<br />

*2<br />

2<br />

*2"<br />

PLUG<br />

(Must be<br />

glued in<br />

place)<br />

−24B−045<br />

−24B−070<br />

−36B−070<br />

−36C−090<br />

−36C−090H<br />

−48C−090<br />

−48C−110<br />

48C−110H<br />

−60C−110<br />

−24B−045<br />

−24B−070<br />

−36B−070<br />

−36C−090<br />

−36C−090H<br />

−48C−090<br />

−48C−110*<br />

−48C−110H*<br />

−60C−110*<br />

−24B−045<br />

−24B−070<br />

−36B−070<br />

−36C−090<br />

−36C−090H<br />

−48C−090<br />

−48C−110<br />

−48C−110H<br />

−60C−110<br />

−60D−135*<br />

*Pipe length must be limited<br />

to 4" in −135 applications.<br />

FIGURE 16<br />

Intake Piping<br />

The G43UF furnace may be installed in either direct vent<br />

or non−direct vent applications. In non−direct vent applications,<br />

when intake air will be drawn into the furnace<br />

from the surrounding space, the indoor air quality must be<br />

considered and guidelines listed in Combustion, Dilution<br />

and Ventilation Air section must be followed.<br />

The G43UF unit is designed for either left−side or right−side<br />

air intake connections. Intake air piping is independent of<br />

exhaust piping.<br />

Follow the next four steps when installing the unit in Direct<br />

Vent applications, where combustion air is taken from<br />

outdoors and flue gases are discharged outdoors. The<br />

provided air intake screen must not be used in direct<br />

vent applications.<br />

1 − Use transition solvent cement to connect PVC pipe to<br />

the ABS slip connector located on the side of the burner<br />

box.<br />

2 − Use a sheet metal screw to secure the intake pipe to<br />

the connector, if desired. A pilot indentation is provided<br />

in the slip connector to assist in locating and<br />

starting the fastener.<br />

3 − Glue the provided 2" ABS plug into the unused ABS air<br />

intake connector on the opposite side of the cabinet with<br />

ABS all pupose cement.<br />

4 − Route piping to outside of structure. Continue with<br />

installation following instructions given in general<br />

guide lines for piping terminations and in intake and<br />

exhaust piping terminations for direct vent sections.<br />

Refer to figure 16 for pipe sizes.<br />

TYPICAL AIR INTAKE PIPE CONNECTIONS<br />

UPFLOW NON−DIRECT<br />

VENT APPLICATIONS<br />

(Right−Hand Exit Shown)<br />

PLUG<br />

(Must be<br />

glued in<br />

place)<br />

FIGURE 17<br />

6 in. Max.<br />

INTAKE<br />

DEBRIS<br />

SCREEN<br />

(Provided)<br />

NOTE − Debris screen and elbow may be rotated, so that<br />

screen may be positioned to face forward, backward or<br />

downward.<br />

Page 17