Troubleshooting: Heating Sequence of Operation<br />

HEATING SEQUENCE OF OPERATION<br />

NORMAL HEATING MODE<br />

ABNORMAL HEATING MODE<br />

POWER ON<br />

CONTROL SELF−CHECK OKAY?<br />

YES<br />

IS POLARITY CORRECT?<br />

YES<br />

IS THERE A PROPER GROUND?<br />

YES<br />

NO<br />

NO<br />

NO<br />

GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.<br />

INDOOR BLOWER DELAY OFF.<br />

LED #1 ON<br />

LED #2 ON<br />

(RESET CONTROL BY TURNING MAIN POWER OFF.)<br />

POLARITY REVERSED.<br />

LED #1 −− FAST FLASH<br />

LED #2 −− SLOW FLASH<br />

IMPROPER GROUND.<br />

LED #1 −− ALTERNATING FAST FLASH<br />

LED #2 −− ALTERNATING FAST FLASH<br />

IS VOLTAGE<br />

ABOVE 90 VOLTS?<br />

NO<br />

LEDs SIGNAL FAST ALTERNATING FLASH.<br />

CONTROL WILL NOT RESPOND TO A CALL FOR<br />

HEATING UNTIL VOLTAGE RISES ABOVE 95 VOLTS.<br />

YES<br />

ROLLOUT SWITCH CLOSED?<br />

YES<br />

NO<br />

GAS VALVE OFF. COMBUSTION AIR INDUCER ON.<br />

INDOOR BLOWER ON.<br />

LED #1 −− ON. LED #2 −− SLOW FLASH.<br />

SEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSES<br />

AND POWER IS RESET OR T’STAT IS INTERRUPTED<br />

FOR MINIMUM OF 1 SECOND.<br />

BURNER OFF?<br />

(CONTINUOUS FLAME CHECK)<br />

YES<br />

NO<br />

GAS VALVE OFF. COMBUSTION AIR INDUCER ON.<br />

INDOOR BLOWER ON HEATING SPEED.<br />

LED #1 −− SLOW FLASH<br />

LED #2 −− OFF<br />

NO<br />

NORMAL OPERATION:<br />

LED #1 −− SLOW FLASH<br />

LED #2 −− SLOW FLASH<br />

YES<br />

THERMOSTAT CALLS FOR HEAT:<br />

LED #1 −− FAST FLASH<br />

LED #2 −− FAST FLASH<br />

YES<br />

NO<br />

COMBUSTION AIR INDUCER OFF.<br />

INDOOR BLOWER ON<br />

LED #1 SLOW FLASH RATE<br />

LED #2 −− ON<br />

PRIMARY AND SECONDARY LIMIT SWITCH.<br />

CLOSED?<br />

YES<br />

IS COMBUSTION AIR<br />

PRESSURE SWITCH OPEN?<br />

YES<br />

IS COMBUSTION AIR INDUCER<br />

ENERGIZED?<br />

NO<br />

GAS VALVE OFF.<br />

COMBUSTION AIR INDUCER OFF.<br />

INDOOR BLOWER OFF WITH DELAY.<br />

LED #1 OFF<br />

LED #2 SLOW FLASH<br />

(Sequence holds until pressure switch<br />

opens or thermostat resets control.)<br />

YES<br />

HAS COMBUSTION AIR PRESSURE<br />

SWITCH CLOSED IN 2.5 MINUTES?<br />

YES<br />

NO<br />

PRESSURE SWITCH IS IN WATCHGUARD MODE.<br />

GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.<br />

INDOOR BLOWER OFF WITH DELAY.<br />

LED #1 −− OFF. LED #2 −− SLOW FLASH.<br />

IS 5-MINUTE RESET PERIOD COMPLETE?<br />

YES<br />