INTEGRATED CONTROL BOARD<br />

(Automatic Hot Surface Ignition System)<br />

HUM<br />

LINE<br />

XFMR<br />

EAC<br />

COOL<br />

HEAT<br />

PARK<br />

FLAME<br />

NEUTRALS<br />

TERMINAL DESIGNATIONS<br />

Humidifier (120VAC)<br />

Input (120VAC)<br />

Transformer (120VAC)<br />

Electronic Air Cleaner (120VAC)<br />

Blower − Cooling Speed (120VAC)<br />

Blower − Heating Speed (120VAC)<br />

Dead terminals to park alternate spd taps<br />

Flame senser<br />

Neutral terminals (120VAC)<br />

3 AMP, 32 VAC FUSE<br />

BLOWER OFF<br />

DELAY JUMPER<br />

FIGURE 42<br />

Unit Start−Up<br />

FOR YOUR SAFETY READ BEFORE OPERATING<br />

WARNING<br />

Do not use this furnace if any part has been underwater.<br />

A flood−damaged furnace is extremely dangerous.<br />

Attempts to use the furnace can result in<br />

fire or explosion. Immediately call a qualified service<br />

technician to inspect the furnace and to replace<br />

all gas controls, control system parts, and electrical<br />

parts that have been wet or to replace the furnace,<br />

if deemed necessary.<br />

WARNING<br />

Danger of explosion. Can cause injury<br />

or product or property damage. Should<br />

the gas supply fail to shut off or if<br />

overheating occurs, shut off the gas<br />

valve to the furnace before shutting off<br />

the electrical supply.<br />

CAUTION<br />

Before attempting to perform any service or maintenance,<br />

turn the electrical power to unit OFF at disconnect<br />

switch.<br />

Priming Condensate Trap<br />

The condensate trap should be primed with water prior to<br />

start−up to ensure proper condensate drainage. Either<br />

pour 10 fl. oz. (300 ml) of water into the trap, or follow<br />

these steps to prime the trap:<br />

1 − Follow the lighting instructions to place the unit into operation.<br />

2 − Set the thermostat to initiate a heating demand.<br />

3 − Allow the burners to fire for approximately 3 minutes.<br />

4 − Adjust the thermostat to deactivate the heating demand.<br />

5 − Wait for the combustion air inducer to stop. Set the<br />

thermostat to initiate a heating demand and again allow<br />

the burners to fire for approximately 3 minutes.<br />

Page 31