INSTALLATION INSTRUCTIONS - Lennox
INSTALLATION INSTRUCTIONS - Lennox
INSTALLATION INSTRUCTIONS - Lennox
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
G43UF and CONDENSING UNIT<br />
THERMOSTAT DESIGNATIONS<br />
(Refer to specific thermostat and outdoor unit.)<br />
Thermostat<br />
R<br />
W1<br />
Y<br />
G<br />
C<br />
POWER<br />
HEAT<br />
COOLING<br />
INDOOR BLOWER<br />
COMMON<br />
G43UF<br />
Furnace<br />
R<br />
W<br />
Y<br />
G<br />
C<br />
FIGURE 39<br />
Condensing<br />
Unit<br />
CONDENSING<br />
UNIT<br />
CONDENSING<br />
UNIT COMMON<br />
Install the room thermostat according to the instructions<br />
provided with the thermostat. See figure 39 for<br />
thermostat designations. If the furnace is being<br />
matched with a heat pump, refer to the FM21 installation<br />
instruction.<br />
Indoor Blower Speeds<br />
1 − When the thermostat is set to FAN ON," the indoor<br />
blower will run continuously on the heating speed<br />
when there is no cooling or heating demand.<br />
2 − When the G43UF is running in the heating mode, the<br />
indoor blower will run on the heating speed.<br />
3 − When there is a cooling demand, the indoor blower will<br />
run on the cooling speed.<br />
TYPICAL G43UF FIELD WIRING DIAGRAM<br />
FIGURE 40<br />
Page 29