Troubleshooting: Continuous Fan Sequence of Operation<br />

CONTINUOUS HEAT SPEED FAN SEQUENCE OF OPERATION<br />

LED: SLOW FLASH RATE REMAINS<br />

UNCHANGED THROUGHOUT SEQUENCE.<br />

MANUAL FAN SELECTION MADE AT THERMOSTAT.<br />

CONTROL (G) ENERGIZES SYSTEM FAN AT HEAT<br />

SPEED. EAC TERMINAL IS ENERGIZED.<br />

THERMOSTAT CALLS FOR HEAT (W).<br />

NO<br />

YES<br />

HUM TERM. ENERGIZES<br />

WITH COMB. AIR INDUCER.<br />

THERMOSTAT CALLS FOR COOLING.<br />

YES<br />

SYSTEM FAN SWITCHED TO COOL SPEED.<br />

EAC TERM. REMAINS ON.<br />

NO<br />

SYSTEM FAN REMAINS ON<br />

HEATING SPEED.<br />

THERMOSTAT OPENS.<br />

THERMOSTAT OPENS.<br />

HUM TERM. DE−ENERGIZES<br />

WITH COMB. AIR INDUCER<br />

MANUAL FAN SELECTION MADE AT THERMOSTAT.<br />

CONTROL (G) ENERGIZES SYSTEM FAN AT HEAT<br />

SPEED. EAC TERM. ENERGIZED.<br />

SYSTEM FAN REMAINS ON<br />

HEATING SPEED.<br />

Repair Parts List<br />

The following repair parts are available through <strong>Lennox</strong> dealers. When ordering parts, include the complete furnace model<br />

number listed on the CSA nameplate −− Example: G43UF−24B−045−3. All service must be performed by a licensed professional<br />

installer (or equivalent), service agency, or gas supplier.<br />

Cabinet Parts<br />

Upper access panel<br />

Blower access panel<br />

Top Cap<br />

Control Panel Parts<br />

Transformer<br />

Integrated control board<br />

Door interlock switch<br />

Blower Parts<br />

Blower wheel<br />

Motor<br />

Motor mounting frame<br />

Motor capacitor<br />

Blower housing cutoff plate<br />

Heating Parts<br />

Flame Sensor<br />

Heat exchanger assembly<br />

Gas manifold<br />

Combustion air inducer<br />

Gas valve<br />

Main burner cluster<br />

Main burner orifices<br />

Pressure switch<br />

Ignitor<br />

Primary limit control<br />

Flame rollout switches<br />

Combustion air inducer auxiliary limit<br />