INSTALLATION INSTRUCTIONS - Lennox
INSTALLATION INSTRUCTIONS - Lennox
INSTALLATION INSTRUCTIONS - Lennox
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
EXHAUST<br />
TERMINATION<br />
INTAKE<br />
TERMINATION<br />
EXHAUST<br />
12" (305) ABOVE<br />
AVERAGE SNOW<br />
ACCUMULATION<br />
INTAKE<br />
FIGURE 22<br />
Inches (mm)<br />
FIELD−PROVIDED<br />
REDUCER MAY BE REQUIRED<br />
TO ADAPT LARGER VENT<br />
PIPE SIZE TO TERMINATION<br />
DIRECT VENT CONCENTRIC ROOFTOP TERMINATION<br />
(71M80, 69M29 or 60L46)<br />
Inches (mm)<br />
FIELD−PROVIDED<br />
REDUCER MAY<br />
BE REQUIRED TO<br />
ADAPT LARGER<br />
VENT PIPE SIZE<br />
TO TERMINATION<br />
EXHAUST<br />
INTAKE<br />
INTAKE<br />
TERMINATION<br />
EXHAUST<br />
TERMINATION<br />
12" (305) Min.<br />
above grade or<br />
average snow<br />
accumulation.<br />
INTAKE<br />
VENT<br />
1/2" (13) Foam Insulation<br />
in Unconditioned Space<br />
FIELD−<br />
PROVIDED<br />
REDUCER MAY<br />
BE REQUIRED<br />
TO ADAPT<br />
LARGER VENT<br />
PIPE SIZE TO<br />
TERMINATION<br />
Inches (mm)<br />
EXHAUST<br />
VENT<br />
INTAKE<br />
VENT<br />
DIRECT VENT WALL TERMINATION KIT<br />
(22G44, 44J40, 30G28 or 81J20)<br />
FIGURE 25<br />
5"<br />
(127)<br />
18" MAX.<br />
(457)<br />
EXHAUST VENT<br />
EXHAUST VENT<br />
5−1/2"<br />
(140)<br />
Front View<br />
Top View<br />
INTAKE VENT<br />
OUTSIDE WALL<br />
12"<br />
(305)<br />
Front View<br />
EXHAUST VENT<br />
DIRECT VENT CONCENTRIC WALL TERMINATION<br />
(71M80, 69M29 or 60L46)<br />
FIGURE 23<br />
Inches (mm)<br />
INTAKE<br />
VENT<br />
Side View<br />
Inches(mm)<br />
UNCONDITIONED<br />
SPACE<br />
OUTSIDE WALL<br />
12" (305) MAX. for 2" (51)<br />
8 (203)<br />
MIN.<br />
OPTIONAL VENT TERMINATION FOR MULTIPLE UNIT<br />
<strong>INSTALLATION</strong> OF DIRECT VENT WALL TERMINATION KIT<br />
(22G44, 44J40, 30G28 or 81J20)<br />
FIGURE 26<br />
PROVIDE SUPPORT<br />
FOR INTAKE AND<br />
EXHAUST LINES EVERY<br />
36" (914)<br />
FIELD−PROVIDED<br />
REDUCER MAY<br />
BE REQUIRED TO<br />
ADAPT LARGER<br />
VENT PIPE SIZE<br />
TO TERMINATION<br />
1/2" (13) FOAM<br />
INSULATION IN<br />
UNCONDITIONED<br />
SPACE<br />
SIDE VIEW<br />
DIRECT VENT WALL RING TERMINATION<br />
(15F74)<br />
See venting table 5 for maximum venting lengths with this arrangement.<br />
FIGURE 24<br />
12" (305) ABOVE<br />
AVERAGE SNOW<br />
ACCUMULATION<br />
1/2" (13) FOAM<br />
INSULATION<br />
SIZE<br />
TERMINATION<br />
PIPE PER<br />
TABLE 6.<br />
Page 22