EXHAUST<br />

TERMINATION<br />

INTAKE<br />

TERMINATION<br />

EXHAUST<br />

12" (305) ABOVE<br />

AVERAGE SNOW<br />

ACCUMULATION<br />

INTAKE<br />

FIGURE 22<br />

Inches (mm)<br />

FIELD−PROVIDED<br />

REDUCER MAY BE REQUIRED<br />

TO ADAPT LARGER VENT<br />

PIPE SIZE TO TERMINATION<br />

DIRECT VENT CONCENTRIC ROOFTOP TERMINATION<br />

(71M80, 69M29 or 60L46)<br />

Inches (mm)<br />

FIELD−PROVIDED<br />

REDUCER MAY<br />

BE REQUIRED TO<br />

ADAPT LARGER<br />

VENT PIPE SIZE<br />

TO TERMINATION<br />

EXHAUST<br />

INTAKE<br />

INTAKE<br />

TERMINATION<br />

EXHAUST<br />

TERMINATION<br />

12" (305) Min.<br />

above grade or<br />

average snow<br />

accumulation.<br />

INTAKE<br />

VENT<br />

1/2" (13) Foam Insulation<br />

in Unconditioned Space<br />

FIELD−<br />

PROVIDED<br />

REDUCER MAY<br />

BE REQUIRED<br />

TO ADAPT<br />

LARGER VENT<br />

PIPE SIZE TO<br />

TERMINATION<br />

Inches (mm)<br />

EXHAUST<br />

VENT<br />

INTAKE<br />

VENT<br />

DIRECT VENT WALL TERMINATION KIT<br />

(22G44, 44J40, 30G28 or 81J20)<br />

FIGURE 25<br />

5"<br />

(127)<br />

18" MAX.<br />

(457)<br />

EXHAUST VENT<br />

EXHAUST VENT<br />

5−1/2"<br />

(140)<br />

Front View<br />

Top View<br />

INTAKE VENT<br />

OUTSIDE WALL<br />

12"<br />

(305)<br />

Front View<br />

EXHAUST VENT<br />

DIRECT VENT CONCENTRIC WALL TERMINATION<br />

(71M80, 69M29 or 60L46)<br />

FIGURE 23<br />

Inches (mm)<br />

INTAKE<br />

VENT<br />

Side View<br />

Inches(mm)<br />

UNCONDITIONED<br />

SPACE<br />

OUTSIDE WALL<br />

12" (305) MAX. for 2" (51)<br />

8 (203)<br />

MIN.<br />

OPTIONAL VENT TERMINATION FOR MULTIPLE UNIT<br />

<strong>INSTALLATION</strong> OF DIRECT VENT WALL TERMINATION KIT<br />

(22G44, 44J40, 30G28 or 81J20)<br />

FIGURE 26<br />

PROVIDE SUPPORT<br />

FOR INTAKE AND<br />

EXHAUST LINES EVERY<br />

36" (914)<br />

FIELD−PROVIDED<br />

REDUCER MAY<br />

BE REQUIRED TO<br />

ADAPT LARGER<br />

VENT PIPE SIZE<br />

TO TERMINATION<br />

1/2" (13) FOAM<br />

INSULATION IN<br />

UNCONDITIONED<br />

SPACE<br />

SIDE VIEW<br />

DIRECT VENT WALL RING TERMINATION<br />

(15F74)<br />

See venting table 5 for maximum venting lengths with this arrangement.<br />

FIGURE 24<br />

12" (305) ABOVE<br />

AVERAGE SNOW<br />

ACCUMULATION<br />

1/2" (13) FOAM<br />

INSULATION<br />

SIZE<br />

TERMINATION<br />

PIPE PER<br />

TABLE 6.<br />

Page 22