26.10.2014 Views

Kalzip® Systems

Kalzip® Systems

Kalzip® Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Kalzip range of applications<br />

Kalzip NatureRoof<br />

Kalzip NatureRoof<br />

All roof designs described above can be<br />

transformed into a Kalzip NatureRoof<br />

providing that the design requirements<br />

are taken into consideration and Kalzip<br />

65/333 is being used. Kalzip NatureRoof<br />

comprises an efficient draining mat to<br />

control the integral water management<br />

and a special substrate sup porting a<br />

vegetation layer for extensive landscaping<br />

with sedum plants. All components for the<br />

Kalzip NatureRoof outside Germany are<br />

available only on request.<br />

Technical data:<br />

Min. roof pitch: 1,5°<br />

Max. roof pitch: 15°<br />

Additional weight (wet): 0.9 kN/m 2<br />

Shear protection: from 5°<br />

Kalzip FOAMGLAS ® System<br />

as a standard solution<br />

Kalzip FOAMGLAS ® System<br />

as a combination solution<br />

* varies depending on thickness and material qualities<br />

Kalzip FOAMGLAS ® System as<br />

a standard and combined solution<br />

This roof design and the system components<br />

used are particularly suitable<br />

for building projects which place high<br />

demands on ensuring that the roof system<br />

is free from condensation and where<br />

there is therefore a permanent risk of<br />

condensation formation. The Kalzip<br />

FOAMGLAS ® System offers a high level of<br />

energy efficiency as the thermal insulation<br />

is airtight and impervious to water vapour.<br />

What’s more, there is no mechanical attachment<br />

between the Kalzip profiled<br />

sheets and the supporting structure. This<br />

means there is no coldbridging. As<br />

FOAMGLAS ® is impervious to moisture<br />

penetration the insulation can also act as<br />

a watertight substructure.<br />

The FOAMGLAS ® slabs are bonded to<br />

different substructures using either a coldbonding<br />

agent or hot bitumen. In order to<br />

attach the composite clips, the galvanized<br />

steel claw plates are inserted under heat<br />

in a fixed installation plan taking into account<br />

the respective roof geometry. The<br />

composite clips are installed on the claw<br />

plates using the recommended fastening<br />

elements. The Kalzip profiled sheets are<br />

installed in the usual manner and are friction-fitted<br />

together. In order to ensure<br />

economic efficiency, the thickness of the<br />

compressible thermal insulation can be<br />

varied. FOAMGLAS ® has a minimum thickness<br />

of 80 mm.<br />

The manufacturer’s installation regulations<br />

are to be observed. The installation and dimensioning<br />

are governed by the Kalzip approval<br />

Z-14.4-475.<br />

Kalzip 19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!