General data and characteristics<br />

5.5 Accessibility/fall arrest systems<br />

For maintenance and cleaning Kalzip<br />

sheets are accessible both during and after<br />

installation without any load distributing<br />

measures. As far as the installation is con -<br />

cerned this will only be valid if the profiled<br />

sheets are zipped on at least one side. The<br />

following table specifies the critical spans<br />

up to which the profiled sheets are accessible<br />

without any additional measures.<br />

It is advisable to install walkways leading<br />

to any units requiring regular maintenance<br />

or operational elements such as daylight<br />

units, chimneys or heating plants. When<br />

exceeding the critical span, load distributing<br />

elements such as wooden planks of<br />

a minium cross section of 4 x 24 cm and<br />

a maximum length of 3 m have to be<br />

installed length – or crosswise over the<br />

Kalzip sheets.<br />

In situations where no rigid thermal insulation<br />

has been installed along the ridge<br />

and eaves areas, the sheets in these parts<br />

of the roof should not directly be walked<br />

on. The reason being that this might lead<br />

to deformation of the flat area of the Kalzip<br />

sheet resulting in a possible accumulation<br />

of rain water.<br />

The last free sheets along the gable end,<br />

single unzipped sheets and of course<br />

translucent panels should not be walked<br />

on. During the installation of the roof any<br />

areas which are frequently walked on or<br />

used for the transport of materials should<br />

be protected by temporary walkways,<br />

which should be secured with seam clips<br />

to prevent them from sliding down.<br />

The Kalzip fall arrest system is a reliable<br />

solution to secure walkways on the finished<br />

roof. It consists of a stainless steel<br />

rope which is fastened to permanently<br />

fixed Kalzip roof anchors and coupled to<br />

the safety harness by means of a guide<br />

link. Project related planning is carried out<br />

by Kalzip GmbH.<br />

Access following installation 1<br />

Seamed Kalzip profile sheets with supporting spacings up to the following dimensions<br />

are accessible without the use of load spreading equipment.<br />

Sheet thickness 65/305 65/333 65/400 50/333 50/429 AF 65/333 2 AF 65/434 2 AS 65/422 2<br />

t/mm lgr/m lgr/m lgr/m lgr/m lgr/m lgr/m lgr/m lgr/m<br />

0.8 2.90 2.90 3.00 2.50 2.50 2.90 3.50 3.50<br />

0.9 3.35 3.35 3.40 2.65 2.60 3.20 3.55 3.55<br />

1.0 3.80 3.80 3.80 2.80 2.70 3.50 3.60 3.60<br />

1.2 3.80 3.80 3.80 3.00 2.90 3.50 3.60 3.60<br />

1<br />

Applies only to stucco-embossed and colour-coated Kalzip profile sheets.<br />

Other material combinations are available on request.<br />

2<br />

On grounds of final visual appearance, this information is only applicable when rigid thermal insulation is used.<br />