© <strong>Siemens</strong> AG 2011<br />

3WL Air Circuit Breakers<br />

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)<br />

General data<br />

Circuit breakers<br />

& <br />

% <br />

$ <br />

# <br />

" <br />

! <br />

<br />

<br />

<br />

' <br />

& <br />

% <br />

$ <br />

5 - ' $ # ><br />

<br />

<br />

! <br />

" <br />

# <br />

$ <br />

% <br />

& <br />

' <br />

<br />

<br />

<br />

! <br />

" <br />

# <br />

(1) Arc chute<br />

(2) Carrying handle<br />

(3) Labeling plates<br />

(4) Motor shutdown switch (option) or<br />

"Electrical ON" (option)<br />

(5) Name plate <strong>for</strong> circuit breaker<br />

(6) Memory status indicator<br />

(7) "Mechanical ON" button<br />

(8) Rated current indication<br />

(9) Positioning pictogram<br />

(10) Operating cycles counter (option)<br />

(11) Hand-operated lever<br />

(12) Crank handle<br />

(13) Withdrawable unit drive shaft<br />

(14) Equipment plate<br />

(15) Ground terminal<br />

(16) Position indicator<br />

(17) Table <strong>for</strong> ground-fault protection<br />

(18) Safety lock <strong>for</strong> crank handle (option)<br />

(19) Mechanical unlocking of<br />

crank handle (option)<br />

(20) Electronic releases<br />

(21) Rated current modules<br />

(22) "Mechanical OFF" button or<br />

"EMERGENCY-STOP" mushroom pushbutton<br />

(option)<br />

(23) Ready-to-close indicator<br />

(24) Switch position indicator<br />

(25) "Tripped" indicator (reset button)<br />

(26) "Secure OFF" locking device (option)<br />

(27) Operator panel<br />

(28) Male connector <strong>for</strong> auxiliary circuit<br />

connections<br />

Guide frames<br />

& <br />

% <br />

$ <br />

# <br />

" <br />

! <br />

<br />

<br />

! <br />

" <br />

# <br />

$ <br />

% <br />

& <br />

(1) Arc chute cover (option)<br />

(2) Blow-out openings<br />

(3) Opening <strong>for</strong> crane hook<br />

(4) Shutter (option)<br />

(5) Locking device (shutter) (option)<br />

(6) Type plate <strong>for</strong> guide frame<br />

(7) Isolating contacts<br />

(8) Ground terminal Ø 14 mm<br />

(9) Locking device <strong>for</strong> racking rail<br />

(10) Locking device against movement when<br />

control cabinet door is open (option)<br />

(11) Door interlocking <strong>for</strong> guide frame<br />

(option)<br />

(12) Racking rail<br />

(13) Factory-set rated current coding<br />

(14) Sliding contact <strong>for</strong> breaker grounding<br />

(option)<br />

(15) Equipment-dependent coding (option)<br />

(16) Shutter actuator (optional)<br />

(17) Position signaling switch (optional)<br />

(18) Sliding contact module <strong>for</strong> auxiliary<br />

conductors (number depends on<br />

equipment)<br />