Configuration Manual for Catalog LV 10.1 · 2012 - Siemens
Configuration Manual for Catalog LV 10.1 · 2012 - Siemens
Configuration Manual for Catalog LV 10.1 · 2012 - Siemens
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
© <strong>Siemens</strong> AG 2011<br />
3WL Air Circuit Breakers<br />
3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)<br />
General data<br />
Circuit breakers<br />
& <br />
% <br />
$ <br />
# <br />
" <br />
! <br />
<br />
<br />
<br />
' <br />
& <br />
% <br />
$ <br />
5 - ' $ # ><br />
<br />
<br />
! <br />
" <br />
# <br />
$ <br />
% <br />
& <br />
' <br />
<br />
<br />
<br />
! <br />
" <br />
# <br />
(1) Arc chute<br />
(2) Carrying handle<br />
(3) Labeling plates<br />
(4) Motor shutdown switch (option) or<br />
"Electrical ON" (option)<br />
(5) Name plate <strong>for</strong> circuit breaker<br />
(6) Memory status indicator<br />
(7) "Mechanical ON" button<br />
(8) Rated current indication<br />
(9) Positioning pictogram<br />
(10) Operating cycles counter (option)<br />
(11) Hand-operated lever<br />
(12) Crank handle<br />
(13) Withdrawable unit drive shaft<br />
(14) Equipment plate<br />
(15) Ground terminal<br />
(16) Position indicator<br />
(17) Table <strong>for</strong> ground-fault protection<br />
(18) Safety lock <strong>for</strong> crank handle (option)<br />
(19) Mechanical unlocking of<br />
crank handle (option)<br />
(20) Electronic releases<br />
(21) Rated current modules<br />
(22) "Mechanical OFF" button or<br />
"EMERGENCY-STOP" mushroom pushbutton<br />
(option)<br />
(23) Ready-to-close indicator<br />
(24) Switch position indicator<br />
(25) "Tripped" indicator (reset button)<br />
(26) "Secure OFF" locking device (option)<br />
(27) Operator panel<br />
(28) Male connector <strong>for</strong> auxiliary circuit<br />
connections<br />
Guide frames<br />
& <br />
% <br />
$ <br />
# <br />
" <br />
! <br />
<br />
<br />
! <br />
" <br />
# <br />
$ <br />
% <br />
& <br />
(1) Arc chute cover (option)<br />
(2) Blow-out openings<br />
(3) Opening <strong>for</strong> crane hook<br />
(4) Shutter (option)<br />
(5) Locking device (shutter) (option)<br />
(6) Type plate <strong>for</strong> guide frame<br />
(7) Isolating contacts<br />
(8) Ground terminal Ø 14 mm<br />
(9) Locking device <strong>for</strong> racking rail<br />
(10) Locking device against movement when<br />
control cabinet door is open (option)<br />
(11) Door interlocking <strong>for</strong> guide frame<br />
(option)<br />
(12) Racking rail<br />
(13) Factory-set rated current coding<br />
(14) Sliding contact <strong>for</strong> breaker grounding<br />
(option)<br />
(15) Equipment-dependent coding (option)<br />
(16) Shutter actuator (optional)<br />
(17) Position signaling switch (optional)<br />
(18) Sliding contact module <strong>for</strong> auxiliary<br />
conductors (number depends on<br />
equipment)<br />
<br />
<br />
' <br />
<br />
5 - ' $ $ ><br />
<strong>Siemens</strong> · <strong>2012</strong><br />
9