3WL Air Circuit Breakers<br />

3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)<br />

Project planning aids<br />

Size II, up to 4000 A, fixed-mounted version, 3 and 4-pole<br />

Standard version<br />

Horizontal connection<br />

NSE0_00633a<br />

4)<br />

5)<br />

Optional connection variants<br />

Front connection (single)<br />

" %<br />

<br />

<br />

<br />

<br />

437,5<br />

16) 17)<br />

270<br />

440<br />

570<br />

1)<br />

85<br />

2)<br />

12)<br />

15)<br />

14)<br />

275<br />

440,5<br />

123,5<br />

10<br />

@ A<br />

$<br />

?<br />

&<br />

5 - $ ! " @<br />

Front connection (double hole)<br />

according to DIN 43673<br />

<br />

<br />

<br />

<br />

<br />

<br />

602<br />

541,5<br />

516<br />

451,5<br />

447<br />

B<br />

C<br />

© <strong>Siemens</strong> AG 2011<br />

" %<br />

<br />

<br />

<br />

<br />

<br />

<br />

a<br />

3)<br />

327,5<br />

461,5<br />

$<br />

5 - $ ! % @<br />

<br />

<br />

<br />

<br />

275<br />

150<br />

a<br />

5,5<br />

76<br />

<br />

<br />

NSE0_02003<br />

150<br />

210<br />

230<br />

45<br />

106<br />

127<br />

6)<br />

?<br />

&<br />

<br />

<br />

<br />

Vertical connection<br />

130<br />

130 130<br />

30<br />

90<br />

30<br />

90<br />

35<br />

11)<br />

<br />

<br />

<br />

b<br />

NSE00641<br />

7)<br />

Ø13,5<br />

3)<br />

7)<br />

3)<br />

3)<br />

139<br />

460<br />

590<br />

NSE00642<br />

90 130 130 130<br />

128<br />

Rated a b c d e f g<br />

circuit breaker<br />

current<br />

A<br />

Up to 2000 10 15 10 11 451 34 541<br />

4000 30 30 20 6 461 39 551<br />

NSE0_00639f<br />

Ø9<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

90 130 130 130<br />

——— 4-pole version<br />

1) Mounting space <strong>for</strong> removal of the arc chutes.<br />

2) Arc quenching space "≤ 690 V" – circuit breaker facing grounded or non-conductive<br />

surfaces.<br />

3) Rivels (4 mm wide, 5 mm deep) <strong>for</strong> supporting phase barriers in the system.<br />

4) Auxiliary connector with SIGUT screw terminals.<br />

5) Auxiliary connector with spring-loaded connection.<br />

6) Dimension to inside surface of the closed cabinet door.<br />

7) Fixing points <strong>for</strong> mounting the circuit breaker in the system.<br />

11) Terminal face.<br />

12) Circuit breaker upper edge, only 1000 V circuit breaker.<br />

14) Space <strong>for</strong> electrical auxiliary circuit connections.<br />

15) Arc quenching space, 300 V circuit breaker facing grounded or non-conductive surfaces.<br />

16) Arc quenching space, 600 V circuit breaker facing grounded or non-conductive surfaces.<br />

17) Arc quenching space, 1000 V circuit breaker (with high arc chute) facing grounded or<br />

non-conductive surfaces.<br />

For safety clearances to grounded parts and to live parts see<br />

page 38.<br />

54 <strong>Siemens</strong> · <strong>2012</strong>